Cold Work Percentage, True Strain and Work-Hardened Strength

Percent cold work and true strain from drawing or rolling reductions, flow stress after cold work by the Hollomon law, and the ideal drawing stress.

Inputs

Examples: Illustrative copper wire 5 to 4 mmSteel strip 3 to 2 mmAluminium rod 10 to 7 mm

Accepted: 0.1 to 1,000 mm
Accepted: 0.1 to 1,000 mm
Accepted: 10 to 3,000 MPa
Accepted: 0.01 to 0.7

Results

%CW = (A₀ − A)/A₀, ε = ln(A₀/A); flow stress K·εⁿ; ideal (frictionless) drawing stress = mean flow stress × ε. Real dies add friction and redundant work, typically 20–50 % more; a pass cannot exceed ε ≈ n + 1 limits in wire drawing (stress below flow stress).

Cold work36.000%
True strain0.44629
Flow stress after cold work206.99MPa
Ideal drawing (or rolling) stress59.984MPa

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative copper wire 5 to 4 mm. The inputs, in the units selected above:

InputValue
Initial diameter (or thickness)5.0000 mm
Final diameter (or thickness)4.0000 mm
Reduction typeRound bar or wire (area ∝ d²)
Strength coefficient320.00 MPa
Strain hardening exponent0.54000 -

Applying the formula below gives:

ResultValue
Cold work36.000 %
True strain0.44629
Flow stress after cold work206.99 MPa
Ideal drawing (or rolling) stress59.984 MPa

Open this example in the calculator and change any input.

Formula

\(\%CW = 1 - \frac{A}{A_0}, \quad \varepsilon = \ln\frac{A_0}{A}, \quad \sigma_f = K\varepsilon^n, \quad \sigma_d = \frac{K\varepsilon^{n+1}}{n + 1}\)

Variables

Symbol Meaning SI unit
\(d_0\) Initial diameter (or thickness) m
\(d_1\) Final diameter (or thickness) m
\(\text{mode}\) Reduction type -
\(K\) Strength coefficient Pa
\(n\) Strain hardening exponent -
\(\%CW\) Cold work -
\(\varepsilon\) True strain -
\(\sigma_f\) Flow stress after cold work Pa
\(\sigma_d\) Ideal drawing (or rolling) stress Pa

Method and standards

Work hardening.

Where it is used

  • Wire and bar drawing schedules.
  • Cold rolling pass planning.

Common mistakes

  • Using engineering strain with Hollomon constants.
  • Ignoring die friction in drawing loads.

Assumptions and limits

  • Homogeneous deformation; Hollomon law.

References

  • Hollomon work hardening and ideal work

Questions and answers

Why use true strain?

True strains add up over successive passes, so total strain is the sum of each pass's ln(A₀/A).

When is annealing needed?

When ductility runs out, usually after 60–90 % cold work for copper and less for harder alloys.

What do the defaults represent?

Illustrative annealed copper (K 320 MPa, n 0.54) drawn from 5 mm to 4 mm wire.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Dieter, Mechanical Metallurgy, 3rd ed. (McGraw-Hill, 1986), ch. 3 and 19

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.