Worked example
Example: Steel bar above Curie, 100 mm in 140 mm coil, 1 kHz. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Workpiece shape | Solid cylinder in a round coil |
| Coil inside diameter (cylinder) | 140.00 mm |
| Workpiece diameter (cylinder) | 100.00 mm |
| Perimeter of the coil opening (slab) | 1,200.0 mm |
| Perimeter of the slab (slab) | 900.00 mm |
| Resistivity of the coil copper (at its temperature) | 0.020000 Ω·mm²/m |
| Resistivity of the workpiece (at its temperature) | 1.2000 Ω·mm²/m |
| Relative permeability of the workpiece | 1.0000 - |
| Frequency | 1,000.0 Hz |
Applying the formula below gives:
| Result | Value |
|---|---|
| Reference depth in the coil copper | 2.2508 mm |
| Reference depth in the workpiece | 17.435 mm |
| Coil electrical efficiency factor | 0.22242 |
| Coil electrical efficiency | 81.805 % |
| Workpiece size to reference depth (cylinder) | 5.7357 |
Open this example in the calculator and change any input.
Formula
\(\eta_{el} = \frac{1}{1 + \frac{D_1'}{D_2'}\sqrt{\frac{\rho_1}{\mu_r\rho_2}}}, \quad D_1' = D_1 + \delta_1, \quad D_2' = D_2 - \delta_2, \quad \delta = \sqrt{\frac{\rho}{\pi f\mu_0\mu_r}}; \quad \text{slab: } \eta_{el} = \frac{1}{1 + \frac{F_1}{F_2}\sqrt{\frac{\rho_1}{\mu_r\rho_2}}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\text{load}\) | Workpiece shape | - |
| \(D_1\) | Coil inside diameter (cylinder) | m |
| \(D_2\) | Workpiece diameter (cylinder) | m |
| \(F_1\) | Perimeter of the coil opening (slab) | m |
| \(F_2\) | Perimeter of the slab (slab) | m |
| \(\rho_1\) | Resistivity of the coil copper (at its temperature) | Ω·m |
| \(\rho_2\) | Resistivity of the workpiece (at its temperature) | Ω·m |
| \(\mu_r\) | Relative permeability of the workpiece | - |
| \(f\) | Frequency | 1/s |
| \(\delta_1\) | Reference depth in the coil copper | m |
| \(\delta_2\) | Reference depth in the workpiece | m |
| \(\text{factor}\) | Coil electrical efficiency factor | - |
| \(\eta_{el}\) | Coil electrical efficiency | - |
| \(D_2/\delta_2\) | Workpiece size to reference depth (cylinder) | - |
Method and standards
Electrical efficiency of a long solenoid coil.
Where it is used
- Coil design for billet, bar and slab heaters.
- Judging the effect of air gap and refractory.
Common mistakes
- Using cold resistivities for hot workpieces.
- Ignoring the drop in μ_r above the Curie point.
Assumptions and limits
- Long single-layer coil; pronounced skin effect.
Questions and answers
Why does a refractory lining lower electrical efficiency?
It widens the coil-to-workpiece gap, so D₁′/D₂′ rises; the lining is still worth it when it cuts heat losses more than it costs in coupling.
Why is steel efficient below the Curie point?
Its relative permeability is in the hundreds, so the workpiece takes far more of the power than the copper coil.
What do the defaults represent?
A 100 mm steel bar above the Curie point (1.2 μΩ·m, μ_r = 1) in a 140 mm coil at 1 kHz, coil copper at 2.0 × 10⁻⁸ Ω·m.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Rudnev, Loveless, Cook and Black, Handbook of Induction Heating (Marcel Dekker, 2003), sec. 3.3.1, eqs. 3.25 and 3.26