The raw data rate is channels × samples per second × bytes per sample, increased by the overhead for timestamps, file headers and the file system. Storage here uses decimal units (1 GB = 10⁹ bytes) as card makers do. Compression, event-triggered logging or storing averages instead of raw samples cut storage by large factors; vibration waveforms at kHz rates fill cards in days while 1 s process trends last for years.

Data rate (kB/s)8.0000
Data per day (MB)691.20
Data for the logging period (GB)20.736
Time to fill the storage46.296d

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 16 channels at 100 S/s. The inputs, in the units selected above:

InputValue
Channels16.000 -
Samples per second per channel100.00 Hz
Bytes per sample4.0000 -
Overhead (timestamps, headers) as a share of the data25.000 %
Logging period30.000 d
Storage capacity (GB)32.000 -

Applying the formula below gives:

ResultValue
Data rate (kB/s)8.0000
Data per day (MB)691.20
Data for the logging period (GB)20.736
Time to fill the storage46.296 d

Open this example in the calculator and change any input.

Formula

\(R = n_c f_s b (1 + k_o), \quad D = R\,t, \quad t_{full} = \frac{C}{R}\)

Variables

Symbol Meaning SI unit
\(n_c\) Channels -
\(f_s\) Samples per second per channel 1/s
\(b\) Bytes per sample -
\(k_o\) Overhead (timestamps, headers) as a share of the data -
\(t\) Logging period s
\(C\) Storage capacity (GB) -
\(R\) Data rate (kB/s) -
\(D_{day}\) Data per day (MB) -
\(D\) Data for the logging period (GB) -
\(t_{full}\) Time to fill the storage s

Method and standards

Data logging.

Where it is used

  • Sizing loggers, historians and condition-monitoring storage.
  • Choosing sampling rates for long campaigns.

Common mistakes

  • Mixing bits and bytes.
  • Ignoring overhead for many small files.

Assumptions and limits

  • Constant sampling; no compression.

References

  • Data volume arithmetic

Questions and answers

How long will 32 GB last?

For 16 channels at 100 samples/s with 4-byte samples and 25 % overhead, about 46 days.

Does a 32 GB card hold 32 × 2³⁰ bytes?

No, card makers use 10⁹ bytes per GB, and the file system takes a little more.

What do the defaults represent?

An illustrative logger with 16 channels at 100 samples/s, 4 bytes each, 25 % overhead, on a 32 GB card for 30 days.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.