FireCADCalc

Instrument Accuracy: % of Span vs % of Reading

Error band of an instrument from an accuracy given as a percentage of span, of full scale or of reading, at a reading, and the error as a share of the reading.

Thermal power plantProcess steam and utilities

Inputs

Examples: 0–100, reading 20, ±0.5 % of span and of reading−50 to 150 °C, reading 25, ±0.25 % span, ±1 % reading0–16 bar, reading 12, ±1 % span

Results

A %-of-span instrument is far less accurate at the bottom of its range: choose the range so normal readings are in the upper half.

Error band by % of span (±)0.50000
Error band by % of reading (±)0.10000
Span accuracy as a share of the reading2.5000%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 0–100, reading 20, ±0.5 % of span and of reading. The inputs, in the units selected above:

InputValue
Lower range value0 -
Upper range value100.00 -
Reading20.000 -
Accuracy as a share of span0.50000 %
Accuracy as a share of reading0.50000 %

Applying the formula below gives:

ResultValue
Error band by % of span (±)0.50000
Error band by % of reading (±)0.10000
Span accuracy as a share of the reading2.5000 %

Open this example in the calculator and change any input.

Formula

\(e_s = a_s\,(x_{hi} - x_{lo}), \quad e_r = a_r\, |x|\)

Variables

Symbol Meaning SI unit
\(x_{lo}\) Lower range value -
\(x_{hi}\) Upper range value -
\(x\) Reading -
\(a_s\) Accuracy as a share of span -
\(a_r\) Accuracy as a share of reading -
\(e_s\) Error band by % of span (±) -
\(e_r\) Error band by % of reading (±) -
\(e_s/x\) Span accuracy as a share of the reading -

Method and standards

Definitions.

Where it is used

  • Instrument selection and range choice.
  • Comparing data sheets.

Common mistakes

  • Treating % span as % reading.
  • Ignoring ambient effects.

Assumptions and limits

  • Accuracy statement only; at a zero reading the relative value is not shown.

References

  • Definitions of accuracy classes (IEC 60770, ISA-51.1 terminology)

Questions and answers

±0.5 % of a 0–100 span at a reading of 20?

±0.5, which is ±2.5 % of the reading.

And ±0.5 % of reading?

±0.1 at 20.

Which is better?

% of reading, at the low end of the range.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.