FireCADCalc

Anti-Aliasing Filter Order for a Required Attenuation

Butterworth filter order needed to attenuate signals that would alias into the band of interest by a required amount, from the sampling rate and pass band.

Inputs

Examples: Illustrative 1 kHz band at 10 kHzTight oversampling 2.56 timesAudio 20 kHz at 48 kHz

Accepted: 0.001 to 10,000,000 kHz
Accepted: 0.0001 to 10,000,000 kHz
Accepted: 1 to 200

Results

A signal at f_s − f_p folds back onto the edge of the band of interest, so the filter must attenuate it by A. A Butterworth filter of order n with its corner at f_p attenuates by 10 log₁₀[1 + (f/f_p)^(2n)], about 6n dB per octave, so n = log₁₀(10^(A/10) − 1)/[2 log₁₀(f_a/f_p)]. Sampling faster moves f_a away and cuts the order needed; that is why oversampling converters need only simple filters.

Lowest frequency that aliases onto f_p28.000kHz
Filter order needed (exact)30.795
Filter order to use31.000
Attenuation at f_a with that order (dB)90.599

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 1 kHz band at 10 kHz. The inputs, in the units selected above:

InputValue
Sampling rate10.000 kHz
Highest frequency of interest (filter corner)1.0000 kHz
Attenuation wanted where aliases would fall on f_p (dB)60.000 -

Applying the formula below gives:

ResultValue
Lowest frequency that aliases onto f_p9.0000 kHz
Filter order needed (exact)3.1439
Filter order to use4.0000
Attenuation at f_a with that order (dB)76.339

Open this example in the calculator and change any input.

Formula

\(A(f) = 10\log_{10}\left[1 + \left(\frac{f}{f_p}\right)^{2n}\right], \quad f_a = f_s - f_p, \quad n = \frac{\log_{10}(10^{A/10} - 1)}{2\log_{10}(f_a/f_p)}\)

Variables

Symbol Meaning SI unit
\(f_s\) Sampling rate 1/s
\(f_p\) Highest frequency of interest (filter corner) 1/s
\(A\) Attenuation wanted where aliases would fall on f_p (dB) -
\(f_a\) Lowest frequency that aliases onto f_p 1/s
\(n\) Filter order needed (exact) -
\(n_{sel}\) Filter order to use -
\(A_{sel}\) Attenuation at f_a with that order (dB) -

Method and standards

Anti-aliasing filter.

Where it is used

  • Data acquisition and vibration measurement.
  • ADC front-end design.

Common mistakes

  • Placing the corner at the Nyquist frequency.
  • Ignoring the filter's own pass-band droop.

Assumptions and limits

  • Butterworth response with the corner at f_p.

References

  • Butterworth magnitude response

Questions and answers

What order filter do I need at 10 kHz sampling for a 1 kHz band and 60 dB?

Aliases start at 9 kHz, a ratio of 9, so 4th order (about 76 dB there) is enough.

How does oversampling help?

It pushes the first alias frequency far above the band, so a low-order filter attenuates it enough.

What do the defaults represent?

An illustrative 1 kHz band sampled at 10 kHz needing 60 dB of alias rejection.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Oppenheim and Schafer, Discrete-Time Signal Processing, 3rd ed. (Pearson, 2010)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.