FireCADCalc

Radiation Unit Converter: Bq–Ci, Gy–rad, Sv–rem, Roentgen

Converts activity (Bq and Ci), absorbed dose (Gy and rad) and equivalent dose (Sv and rem), and exposure in roentgen to C/kg and air kerma.

Inputs

Examples: Illustrative 1 Ci, 10 microgray, 1 RAlpha dose 2 mGy, weighting 20Radiography source 100 Ci, 50 mR

Accepted: 0 to 1E+11 GBq
Accepted: 0 to 10,000,000 mGy
Accepted: 1 to 20
Accepted: 0 to 1,000,000

Results

1 Ci = 3.7 × 10¹⁰ Bq (exact); 1 rad = 0.01 Gy; 1 rem = 0.01 Sv. Equivalent dose H = w_R·D (w_R = 1 for photons and electrons, 20 for alpha particles; neutrons depend on energy). 1 R = 2.58 × 10⁻⁴ C/kg of air (exact), and with W/e = 33.97 J/C for dry air, 1 R corresponds to about 8.76 mGy air kerma. Effective dose needs tissue weighting factors as well.

Activity (Ci)1.0000Ci
Activity (mCi)1,000.0mCi
Absorbed dose (rad)0.001000rad
Equivalent dose (mSv)0.010000mSv
Equivalent dose (rem)0.001000rem
Exposure (mC/kg)0.25800
Air kerma for the exposure8.7643mGy

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 1 Ci, 10 microgray, 1 R. The inputs, in the units selected above:

InputValue
Activity37.000 GBq
Absorbed dose0.010000 mGy
Radiation weighting factor1.0000 -
Exposure (roentgen)1.0000 -

Applying the formula below gives:

ResultValue
Activity (Ci)1.0000 Ci
Activity (mCi)1,000.0 mCi
Absorbed dose (rad)0.001000 rad
Equivalent dose (mSv)0.010000 mSv
Equivalent dose (rem)0.001000 rem
Exposure (mC/kg)0.25800
Air kerma for the exposure8.7643 mGy

Open this example in the calculator and change any input.

Formula

\(1\ \text{Ci} = 3.7\times10^{10}\ \text{Bq}, \quad H = w_RD, \quad 1\ \text{R} = 2.58\times10^{-4}\ \text{C/kg}\)

Variables

Symbol Meaning SI unit
\(A\) Activity Bq
\(D\) Absorbed dose Gy
\(w_R\) Radiation weighting factor -
\(X\) Exposure (roentgen) -
\(H\) Equivalent dose (mSv) Gy
\(K_{air}\) Air kerma for the exposure Gy

Method and standards

Radiation units.

Where it is used

  • Reading older radiation records and source certificates.
  • Health physics and radiography.

Common mistakes

  • Treating Gy and Sv as identical for alpha or neutrons.
  • Equating roentgen and rad exactly.

Assumptions and limits

  • Exact definitions; air W/e = 33.97 J/C.

References

  • SI and legacy radiation units; radiation weighting

Questions and answers

What is the difference between gray and sievert?

Gray is energy absorbed per kilogram; sievert weights it by how harmful the radiation type is.

Is a roentgen the same as a rad?

Not quite: 1 R of exposure gives about 0.876 rad in air and about 0.96 rad in soft tissue for typical gamma rays.

What do the defaults represent?

Illustrative values: 1 Ci (37 GBq) of activity, 10 µGy of gamma dose and 1 R of exposure.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Thompson and Taylor, Guide for the Use of the International System of Units, NIST SP 811 (2008), ICRP Publication 103, The 2007 Recommendations of the International Commission on Radiological Protection (2007)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.