FireCADCalc

Magnetic Unit Converter: Tesla, Gauss, A/m and Oersted

Converts flux density between tesla and gauss and field strength between A/m and oersted, and relates B and H through the relative permeability.

Inputs

Examples: Illustrative Earth-field and 1000 OeElectrical steel at mu_r 4000NdFeB magnet surface

Accepted: 0 to 100,000 mT
Accepted: 0 to 12,566,000 Oe
Accepted: 1 to 1,000,000

Results

1 T = 10⁴ G; 1 Oe = 1000/(4π) A/m ≈ 79.58 A/m. In vacuum (and air) B = μ₀H, so 1 G corresponds to 1 Oe; in a linear material B = μ₀μ_rH. Ferromagnetic materials are non-linear and saturate, so a single μ_r is only valid at one operating point. The Earth's field is about 0.25–0.65 G (25–65 µT).

Flux density in gauss0.50000G
Flux density in tesla5.0000e-05T
Field strength in oersted1,000.0Oe
Field strength in kA/m79.577kA/m
H corresponding to B in the medium39.789A/m
B corresponding to H in the medium100.00mT

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative Earth-field and 1000 Oe. The inputs, in the units selected above:

InputValue
Magnetic flux density0.050000 mT
Magnetic field strength1,000.0 Oe
Relative permeability of the medium1.0000 -

Applying the formula below gives:

ResultValue
Flux density in gauss0.50000 G
Flux density in tesla5.0000e-05 T
Field strength in oersted1,000.0 Oe
Field strength in kA/m79.577 kA/m
H corresponding to B in the medium39.789 A/m
B corresponding to H in the medium100.00 mT

Open this example in the calculator and change any input.

Formula

\(1\ \text{T} = 10^4\ \text{G}, \quad 1\ \text{Oe} = \frac{1000}{4\pi}\ \text{A/m}, \quad B = \mu_0\mu_rH\)

Variables

Symbol Meaning SI unit
\(B\) Magnetic flux density T
\(H\) Magnetic field strength A/m
\(\mu_r\) Relative permeability of the medium -
\(H_B\) H corresponding to B in the medium A/m
\(B_H\) B corresponding to H in the medium T

Method and standards

Magnetic units.

Where it is used

  • Reading older magnetic data.
  • Magnet and sensor specifications.

Common mistakes

  • Treating B and H as the same quantity in materials.
  • Using one μ_r for saturating iron.

Assumptions and limits

  • Linear isotropic medium for the B–H relation.

References

  • SI and CGS magnetic units

Questions and answers

Are gauss and oersted the same?

Numerically equal in vacuum or air, but they measure different quantities (B and H).

Why does the permeability matter?

In magnetic materials the same H produces a much larger B.

What do the defaults represent?

An illustrative 0.05 mT (0.5 G, roughly the Earth's field) and 1,000 Oe in air.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Thompson and Taylor, Guide for the Use of the International System of Units, NIST SP 811 (2008)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.