FireCADCalc

Monthly Utilizability φ̄ (Klein) and Utilizable Solar Energy

Monthly average daily utilizability of radiation on a tilted collector above a critical level by Klein's correlation, and the month's utilizable or collected energy.

Process steam and utilitiesFood, dairy and textile

Inputs

Examples: Process-heat collector at Pune 18.5 N, January, 25 deg, critical 250 W/m2, FR(ta) 0.70Southern hemisphere 34 S, July, 50 deg north-facing, critical 100 W/m2

Accepted: -89 to 89 °
Accepted: 1 to 365
Accepted: 0.1 to 40 MJ/m²
Accepted: 0 to 90 °
Accepted: 0 to 100 %
Accepted: 0 to 1,500 W/m²
Accepted: 28 to 31
Accepted: 0 to 100 %

Results

Klein (1978) correlation for equator-facing surfaces; the noon-day quantities use the average day (H = H̄) with the Erbs daily diffuse fraction and the monthly R̄ the Erbs monthly fraction, in common practice. For a collector the critical level is F_RU_L(T_i − T̄_a)/F_R(τα).

Monthly clearness index0.54130
Monthly ratio tilted to horizontal1.6619
Noon ratio on the average day1.3680
Dimensionless critical level0.16605
Monthly utilizability77.738%
Daily radiation on the collector15.788MJ/m²
Utilizable energy in the month380.46MJ/m²

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Process-heat collector at Pune 18.5 N, January, 25 deg, critical 250 W/m2, FR(ta) 0.70. The inputs, in the units selected above:

InputValue
Latitude18.500 °
Mean day of the month17.000 -
Monthly average daily radiation on a horizontal surface19.500 MJ/m²
Collector slope (facing the equator)25.000 °
Ground reflectance20.000 %
Critical radiation level250.00 W/m²
Days in the month31.000 -
Collector F_R(τα), monthly mean (0 = utilizable radiation only)70.000 %

Applying the formula below gives:

ResultValue
Monthly clearness index0.70308
Monthly ratio tilted to horizontal1.2752
Noon ratio on the average day1.1992
Dimensionless critical level0.25214
Monthly utilizability62.090 %
Daily radiation on the collector24.867 MJ/m²
Utilizable energy in the month478.63 MJ/m²
Collected energy per m² (if F_R(τα) given)335.04 MJ/m²

Open this example in the calculator and change any input.

Formula

\(\bar\phi = \exp\left\{\left[a + b\frac{R_n}{\bar R}\right]\left[\bar X_c + c\bar X_c^2\right]\right\}, \quad \bar X_c = \frac{I_{Tc}}{r_{t,n}R_n\bar H}\)

\(a = 2.943 - 9.271\bar K_T + 4.031\bar K_T^2, \ b = -4.345 + 8.853\bar K_T - 3.602\bar K_T^2, \ c = -0.170 - 0.306\bar K_T + 2.936\bar K_T^2\)

Variables

Symbol Meaning SI unit
\(\phi\) Latitude rad
\(n\) Mean day of the month -
\(\bar H\) Monthly average daily radiation on a horizontal surface J/m²
\(\beta\) Collector slope (facing the equator) rad
\(\rho_g\) Ground reflectance -
\(I_{T,c}\) Critical radiation level W/m²
\(N\) Days in the month -
\(F_R(\bar{\tau\alpha})\) Collector F_R(τα), monthly mean (0 = utilizable radiation only) -
\(\bar K_T\) Monthly clearness index -
\(\bar R\) Monthly ratio tilted to horizontal -
\(R_n\) Noon ratio on the average day -
\(\bar X_c\) Dimensionless critical level -
\(\bar\phi\) Monthly utilizability -
\(\bar H_T\) Daily radiation on the collector J/m²
\(\bar H_TN\bar\phi\) Utilizable energy in the month J/m²
\(Q_u/A_c\) Collected energy per m² (if F_R(τα) given) J/m²

Method and standards

Klein's monthly average daily utilizability.

Where it is used

  • Monthly output of collectors at constant inlet temperature (process heat).
  • Passive solar and storage-limited systems.

Common mistakes

  • Using the clear-day noon radiation for R_n.
  • Using an hourly critical level in J/m² without converting.

Assumptions and limits

  • Equator-facing surfaces; monthly averages.

Questions and answers

What is utilizability?

The fraction of the month's radiation on the collector that exceeds a critical level, the level at which the collector's gains just equal its losses.

How do I get the critical level?

I_Tc = F_RU_L(T_i − T̄_a)/F_R(τα); a collector feeding a process at a constant inlet temperature collects F_R(τα)H̄_TNφ̄ per m².

What do the defaults represent?

An illustrative case: Process-heat collector at Pune 18.5 N, January, 25 deg, critical 250 W/m2, FR(ta) 0.70. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Duffie and Beckman, Solar Engineering of Thermal Processes, 4th ed. (Wiley, 2013), sec. 2.24, eqs. 2.24.2 to 2.24.4 (Klein, 1978) and Example 2.24.1

Related calculators