Worked example
Example: Illustrative 1000 MWh_e, 40 %, 290-565 C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Electrical energy to deliver from storage | 1,000.0 MWh |
| Power cycle efficiency (1 for heat delivered as heat) | 40.000 % |
| Hot tank temperature | 565.00 °C |
| Cold tank temperature | 290.00 °C |
| Salt mean specific heat (solar salt about 1,500) | 1.5000 kJ/(kg·K) |
| Salt mean density (solar salt about 1,800–1,900) | 1,850.0 kg/m³ |
| Tank volume margin (heel and freeboard) | 1.1000 - |
| Tank liquid height | 12.000 m |
Applying the formula below gives:
| Result | Value |
|---|---|
| Thermal energy stored | 2,500.0 MWh |
| Salt mass | 21,818 t |
| Salt volume | 11,794 m³ |
| Volume of each tank with margin | 12,973 m³ |
| Tank diameter for the height entered | 37.101 m |
| Storage density (kWh thermal per m³ of salt) | 211.98 |
Open this example in the calculator and change any input.
Formula
\(Q = \frac{E_e}{\eta}, \quad m = \frac{Q}{c_p(T_h - T_c)}, \quad D_t = \sqrt{\frac{4fV}{\pi H}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(E_e\) | Electrical energy to deliver from storage | J |
| \(\eta\) | Power cycle efficiency (1 for heat delivered as heat) | - |
| \(T_h\) | Hot tank temperature | K |
| \(T_c\) | Cold tank temperature | K |
| \(c_p\) | Salt mean specific heat (solar salt about 1,500) | J/(kg·K) |
| \(\rho\) | Salt mean density (solar salt about 1,800–1,900) | kg/m³ |
| \(f\) | Tank volume margin (heel and freeboard) | - |
| \(H\) | Tank liquid height | m |
| \(Q\) | Thermal energy stored | J |
| \(m\) | Salt mass | kg |
| \(V\) | Salt volume | m³ |
| \(V_t\) | Volume of each tank with margin | m³ |
| \(D_t\) | Tank diameter for the height entered | m |
| \(e\) | Storage density (kWh thermal per m³ of salt) | - |
Method and standards
Sensible storage sizing.
Where it is used
- Concentrating solar power plant design.
- Industrial heat storage.
Common mistakes
- Forgetting the tank heel that never drains.
- Using the electric energy as the thermal energy.
Assumptions and limits
- Constant c_p; perfect stratification between tanks.
References
- Sensible heat storage energy balance
Questions and answers
How much salt does a CSP plant need?
About 22,000 t per 1,000 MWh of electricity with a 290–565 °C tank pair and a 40 % cycle.
Why is molten salt storage cheaper than batteries for CSP?
Heat is stored before conversion in cheap nitrate salt in steel tanks; the turbine already exists, so storage hours add only salt and tanks.
What do the defaults represent?
An illustrative 1,000 MWh of electricity (for example 100 MW for 10 hours) with a 40 % cycle and solar salt between 290 and 565 °C.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Twidell and Weir, Renewable Energy Resources, 2nd ed. (Taylor and Francis, 2006), Kothari, Singal and Ranjan, Renewable Energy Sources and Emerging Technologies, 2nd ed. (PHI, 2011)