Heliostat Cosine Efficiency and Atmospheric Attenuation

Cosine efficiency of a heliostat from sun position and its location relative to the tower receiver, with the slant range and atmospheric attenuation.

Thermal power plant

Inputs

Examples: Illustrative heliostat 300 m north, sun south at 50 degSouth field 300 m south, morning sun east 30 degFar east heliostat 800 m, noon 60 deg

Accepted: 0.57296 to 89.954 °
Accepted: 0 to 360 °
Accepted: -3,000 to 3,000 m
Accepted: -3,000 to 3,000 m
Accepted: 5 to 400 m

Results

The mirror normal bisects the sun direction and the direction to the receiver: cos θ = √[(1 + ŝ·t̂)/2]. Attenuation by a common clear-day fit, 0.99321 − 1.176 × 10⁻⁴S + 1.97 × 10⁻⁸S² (S in m, up to 1 km). Heliostats north of the tower (in the northern hemisphere) have the best cosine efficiency.

Cosine efficiency97.916%
Incidence angle on the mirror11.717°
Slant range to the receiver335.41m
Atmospheric transmission95.598%
Product93.606%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative heliostat 300 m north, sun south at 50 deg. The inputs, in the units selected above:

InputValue
Sun elevation50.000 °
Sun azimuth (clockwise from north)180.00 °
Heliostat position east of the tower0 m
Heliostat position north of the tower300.00 m
Receiver height above the heliostat150.00 m

Applying the formula below gives:

ResultValue
Cosine efficiency97.916 %
Incidence angle on the mirror11.717 °
Slant range to the receiver335.41 m
Atmospheric transmission95.598 %
Product93.606 %

Open this example in the calculator and change any input.

Formula

\(\cos\theta = \sqrt{\frac{1 + \hat s\cdot\hat t}{2}}, \quad \eta_{att} = 0.99321 - 1.176\times10^{-4}S + 1.97\times10^{-8}S^2\)

Variables

Symbol Meaning SI unit
\(\alpha_s\) Sun elevation rad
\(\gamma_s\) Sun azimuth (clockwise from north) rad
\(x\) Heliostat position east of the tower m
\(y\) Heliostat position north of the tower m
\(H\) Receiver height above the heliostat m
\(\cos\theta\) Cosine efficiency -
\(\theta\) Incidence angle on the mirror rad
\(S\) Slant range to the receiver m
\(\eta_{att}\) Atmospheric transmission -
\(\eta_{cos}\eta_{att}\) Product -

Method and standards

Heliostat geometry.

Where it is used

  • Solar tower field layout.
  • Teaching CSP optics.

Common mistakes

  • Using the sun's incidence on a horizontal mirror.
  • Ignoring attenuation in large fields.

Assumptions and limits

  • Flat ideal mirror; clear atmosphere.

References

  • Heliostat geometry and atmospheric attenuation

Questions and answers

Why are tower fields mostly north of the tower?

In the northern hemisphere the sun is to the south; mirrors north of the tower face it more squarely when reflecting back towards the tower, giving high cosine efficiency.

How much light is lost in the air?

About 2 % at 100 m and 7 % at 600 m on a clear day by this fit, more in dusty or humid air.

What do the defaults represent?

An illustrative heliostat 300 m north of a tower with the receiver 150 m above it, sun due south at 50° elevation.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Duffie and Beckman, Solar Engineering of Thermal Processes, 4th ed. (Wiley, 2013), ch. 7

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.