FireCADCalc

Solar Glazing Transmittance and (τα) Product for N Covers

Reflection and absorption losses of one to four solar collector covers at any incidence angle, diffuse reflectance and the transmittance-absorptance product.

Process steam and utilitiesFood, dairy and textile

Inputs

Examples: One low-iron cover at normal incidence, KL 0.012, alpha 0.95Polycarbonate (n 1.60) single cover at 30 deg, KL 0.06, alpha 0.92

Accepted: 0 to 89 °
Accepted: 1 to 3
Accepted: 1 to 4
Accepted: 0 to 1
Accepted: 0 to 100 %

Results

τ ≈ τ_r τ_a for identical covers; the diffuse reflectance is taken at the 60° effective angle for radiation reflected back from the plate. (τα) ≈ 1.01 τα is a good check.

Refraction angle0°
Interface reflectance, perpendicular0.043362
Interface reflectance, parallel0.043362
Transmittance for reflection losses0.91688
Transmittance for absorption losses0.98807
Cover system transmittance0.90594
Diffuse reflectance of the covers (at 60°)0.15562
Transmittance-absorptance product0.86740

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: One low-iron cover at normal incidence, KL 0.012, alpha 0.95. The inputs, in the units selected above:

InputValue
Angle of incidence0 °
Refractive index of the cover (glass 1.526)1.5260 -
Number of covers1.0000 -
Extinction coefficient times thickness, per cover (glass 2.3 mm: 0.037 to 0.074)0.012000 -
Absorptance of the absorber plate95.000 %

Applying the formula below gives:

ResultValue
Refraction angle0 °
Interface reflectance, perpendicular0.043362
Interface reflectance, parallel0.043362
Transmittance for reflection losses0.91688
Transmittance for absorption losses0.98807
Cover system transmittance0.90594
Diffuse reflectance of the covers (at 60°)0.15562
Transmittance-absorptance product0.86740

Open this example in the calculator and change any input.

Formula

\(r_\perp = \frac{\sin^2(\theta_2 - \theta_1)}{\sin^2(\theta_2 + \theta_1)}, \quad r_\parallel = \frac{\tan^2(\theta_2 - \theta_1)}{\tan^2(\theta_2 + \theta_1)}, \quad n = \frac{\sin\theta_1}{\sin\theta_2}\)

\(\tau_r = \frac12\left[\frac{1 - r_\parallel}{1 + (2N - 1)r_\parallel} + \frac{1 - r_\perp}{1 + (2N - 1)r_\perp}\right], \quad \tau_a = e^{-NKL/\cos\theta_2}, \quad (\tau\alpha) = \frac{\tau\alpha}{1 - (1 - \alpha)\rho_d}\)

Variables

Symbol Meaning SI unit
\(\theta_1\) Angle of incidence rad
\(n\) Refractive index of the cover (glass 1.526) -
\(N\) Number of covers -
\(KL\) Extinction coefficient times thickness, per cover (glass 2.3 mm: 0.037 to 0.074) -
\(\alpha\) Absorptance of the absorber plate -
\(\theta_2\) Refraction angle rad
\(r_\perp\) Interface reflectance, perpendicular -
\(r_\parallel\) Interface reflectance, parallel -
\(\tau_r\) Transmittance for reflection losses -
\(\tau_a\) Transmittance for absorption losses -
\(\tau\) Cover system transmittance -
\(\rho_d\) Diffuse reflectance of the covers (at 60°) -
\((\tau\alpha)\) Transmittance-absorptance product -

Method and standards

Fresnel reflection, Bouguer absorption and multiple reflection between plate and covers.

Where it is used

  • Optical efficiency of flat-plate collectors and greenhouse glazing.
  • Choosing low-iron or anti-reflective glass.

Common mistakes

  • Adding reflectances of the two polarisations instead of averaging transmittances.
  • Ignoring absorption in thick or iron-rich glass.

Assumptions and limits

  • Specular, non-scattering covers of equal properties; solar-spectrum average index.

Questions and answers

Why do two covers transmit less but sometimes perform better?

Each cover loses about 8 % by reflection, but a second cover roughly halves the top loss; at high operating temperatures or cold climates the second cover wins.

What is KL for glass?

Water-white low-iron glass has K about 4 m⁻¹, ordinary float glass 16–32 m⁻¹; with 3 mm thickness KL is 0.01–0.1.

What do the defaults represent?

An illustrative case: One low-iron cover at normal incidence, KL 0.012, alpha 0.95. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Duffie and Beckman, Solar Engineering of Thermal Processes, 4th ed. (Wiley, 2013), secs. 5.1 to 5.5, eqs. 5.1.3 to 5.1.9, 5.2.2, 5.3.4, 5.3.6 and 5.5.1 and Examples 5.1.1, 5.1.2, 5.3.2 and 5.5.1

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.