Worked example
Example: Illustrative 20 deg, 200 mm aperture. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Acceptance half-angle | 20.000 ° |
| Aperture width (2D) or diameter (3D) | 0.20000 m |
Applying the formula below gives:
| Result | Value |
|---|---|
| Ideal 2D (trough) concentration 1/sin θ | 2.9238 |
| Ideal 3D (cone) concentration 1/sin²θ | 8.5486 |
| Absorber width for 2D | 68.404 mm |
| Hours per day a fixed east-west trough sees the sun (2θ/15°) | 2.6667 |
| Limit for the sun's disc (2D) | 214.59 |
Open this example in the calculator and change any input.
Formula
\(C_{2D} = \frac{1}{\sin\theta_a}, \quad C_{3D} = \frac{1}{\sin^2\theta_a}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\theta_a\) | Acceptance half-angle | rad |
| \(W\) | Aperture width (2D) or diameter (3D) | m |
| \(C_{2D}\) | Ideal 2D (trough) concentration 1/sin θ | - |
| \(C_{3D}\) | Ideal 3D (cone) concentration 1/sin²θ | - |
| \(w\) | Absorber width for 2D | m |
| \(\Delta t\) | Hours per day a fixed east-west trough sees the sun (2θ/15°) | - |
| \(C_{max,2D}\) | Limit for the sun's disc (2D) | - |
Method and standards
Non-imaging concentration.
Where it is used
- Evacuated-tube and medium-temperature collectors.
- Teaching concentration limits.
Common mistakes
- Expecting point-focus concentration from a trough.
- Ignoring truncation and reflectance losses.
Assumptions and limits
- Ideal untruncated concentrator.
References
- Ideal non-imaging concentration
Questions and answers
Why can a CPC work without tracking?
With an acceptance half-angle of 20–35° it collects the sun for many hours a day and diffuse light within that cone, at a modest concentration of 2–3.
What is the highest possible concentration?
About 215 for troughs and 46,000 for point focus, set by the sun's angular size.
What do the defaults represent?
An illustrative 2D CPC with a 20° acceptance half-angle and a 200 mm aperture.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Duffie and Beckman, Solar Engineering of Thermal Processes, 4th ed. (Wiley, 2013), ch. 7