Worked example
Example: Four 2.5 m2 water collectors at 0.05 kg/s. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Collectors in series | 4.0000 - |
| Area of one collector | 2.5000 m² |
| Single collector F_R(τα) | 75.000 % |
| Single collector F_R U_L | 4.5000 W/(m²·K) |
| Flow through the string | 0.050000 kg/s |
| Fluid specific heat | 4.1800 kJ/(kg·K) |
Applying the formula below gives:
| Result | Value |
|---|---|
| Single-collector parameter A₁F_RU_L/ṁc_p | 0.053828 |
| Series reduction factor | 92.212 % |
| Combined F_R(τα) | 69.159 % |
| Combined F_R U_L | 4.1495 W/(m²·K) |
| Total area | 10.000 m² |
Open this example in the calculator and change any input.
Formula
\(K = \frac{A_1F_RU_L}{\dot mc_p}, \quad F_R(\tau\alpha)_N = F_R(\tau\alpha)_1\frac{1 - (1 - K)^N}{NK}, \quad F_RU_{L,N} = F_RU_{L,1}\frac{1 - (1 - K)^N}{NK}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(N\) | Collectors in series | - |
| \(A_1\) | Area of one collector | m² |
| \(F_R(\tau\alpha)\) | Single collector F_R(τα) | - |
| \(F_RU_L\) | Single collector F_R U_L | W/(m²·K) |
| \(\dot m\) | Flow through the string | kg/s |
| \(c_p\) | Fluid specific heat | J/(kg·K) |
| \(K\) | Single-collector parameter A₁F_RU_L/ṁc_p | - |
| \(\frac{1 - (1 - K)^N}{NK}\) | Series reduction factor | - |
| \(F_R(\tau\alpha)_{series}\) | Combined F_R(τα) | - |
| \(F_RU_{L,series}\) | Combined F_R U_L | W/(m²·K) |
| \(A\) | Total area | m² |
Method and standards
Series combination of identical linear collectors.
Where it is used
- Array layout decisions.
- Air heater strings.
Common mistakes
- Using test parameters at a different flow than in the string.
- Adding the areas without reducing F_R.
Assumptions and limits
- Identical collectors, linear efficiency, same flow through all.
Questions and answers
Why do series collectors perform worse per square metre?
Each later collector receives warmer fluid, so its losses are higher; the combined F_R falls below that of one collector.
Does it depend on air or liquid?
No, the method holds for both; K is larger for air heaters because of their low ṁc_p, so the penalty is bigger.
What do the defaults represent?
An illustrative case: Four 2.5 m2 water collectors at 0.05 kg/s. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.