Worked example
Example: Selective plate 0.10, one cover, 60 C, 20 C, wind 15. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Number of glass covers | 1.0000 - |
| Plate emittance (selective 0.1, black paint 0.95) | 10.000 % |
| Glass emittance | 88.000 % |
| Collector slope | 30.000 ° |
| Mean plate temperature | 60.000 °C |
| Ambient temperature | 20.000 °C |
| Wind heat transfer coefficient (about 5.7 + 3.8V) | 15.000 W/(m²·K) |
| Back insulation conductivity | 0.040000 W/(m·K) |
| Back insulation thickness | 50.000 mm |
| Edge loss coefficient, referred to collector area | 0.20000 W/(m²·K) |
Applying the formula below gives:
| Result | Value |
|---|---|
| Klein factor f | 2.3300 |
| Klein factor C | 496.13 |
| Klein exponent e | 0.30093 |
| Top loss, convective part | 2.6010 W/(m²·K) |
| Top loss, radiative part | 0.86340 W/(m²·K) |
| Top loss coefficient | 3.4644 W/(m²·K) |
| Back loss coefficient | 0.80000 W/(m²·K) |
| Overall loss coefficient | 4.4644 W/(m²·K) |
| Heat loss per unit area at these temperatures | 178.58 W/m² |
Open this example in the calculator and change any input.
Formula
\(U_t = \left[\frac{N}{\frac{C}{T_{pm}}\left(\frac{T_{pm} - T_a}{N + f}\right)^e} + \frac{1}{h_w}\right]^{-1} + \frac{\sigma(T_{pm} + T_a)(T_{pm}^2 + T_a^2)}{(\varepsilon_p + 0.00591Nh_w)^{-1} + \frac{2N + f - 1 + 0.133\varepsilon_p}{\varepsilon_g} - N}\)
\(f = (1 + 0.089h_w - 0.1166h_w\varepsilon_p)(1 + 0.07866N), \quad C = 520(1 - 0.000051\beta^2), \quad e = 0.430\left(1 - \frac{100}{T_{pm}}\right), \quad U_L = U_t + \frac{k}{L} + U_e\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(N\) | Number of glass covers | - |
| \(\varepsilon_p\) | Plate emittance (selective 0.1, black paint 0.95) | - |
| \(\varepsilon_g\) | Glass emittance | - |
| \(\beta\) | Collector slope | rad |
| \(T_{pm}\) | Mean plate temperature | K |
| \(T_a\) | Ambient temperature | K |
| \(h_w\) | Wind heat transfer coefficient (about 5.7 + 3.8V) | W/(m²·K) |
| \(k_b\) | Back insulation conductivity | W/(m·K) |
| \(L_b\) | Back insulation thickness | m |
| \(U_e\) | Edge loss coefficient, referred to collector area | W/(m²·K) |
| \(f\) | Klein factor f | - |
| \(C\) | Klein factor C | - |
| \(e\) | Klein exponent e | - |
| \(U_{t,conv}\) | Top loss, convective part | W/(m²·K) |
| \(U_{t,rad}\) | Top loss, radiative part | W/(m²·K) |
| \(U_t\) | Top loss coefficient | W/(m²·K) |
| \(U_b\) | Back loss coefficient | W/(m²·K) |
| \(U_L\) | Overall loss coefficient | W/(m²·K) |
| \(q_L\) | Heat loss per unit area at these temperatures | W/m² |
Method and standards
Klein's empirical fit to the cover-by-cover top loss calculation.
Where it is used
- Estimating U_L for collector design or when test data are missing.
- Comparing one and two covers or a selective absorber.
Common mistakes
- Entering temperatures in °C in the Klein equation (it needs kelvin).
- Forgetting the back and edge losses.
Assumptions and limits
- Plate-to-cover gap about 25 mm; slope above 70° treated as 70°.
Questions and answers
How much does a selective surface help?
Dropping the plate emittance from 0.95 to 0.10 roughly halves the top loss of a single-glazed collector at 100 °C, because radiation is about half of it.
What wind coefficient should I use?
McAdams' h = 5.7 + 3.8V (V in m/s) is widely used though it includes some radiation; Designers suggest h = max(5, 8.6V0.6/L0.4).
What do the defaults represent?
An illustrative case: Selective plate 0.10, one cover, 60 C, 20 C, wind 15. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Duffie and Beckman, Solar Engineering of Thermal Processes, 4th ed. (Wiley, 2013), sec. 6.4, eq. 6.4.9 (Klein, 1979) and Example 6.4.2