FireCADCalc

Collector Row Shading: Shaded Fraction and Clear Row Spacing

Fraction of a sloped collector shaded by the row in front at a given profile angle, the angle at which shading starts and the row pitch that avoids it.

Process steam and utilitiesFood, dairy and textile

Inputs

Examples: PV 2 m at 25 deg, pitch 4.5 m, profile 20 deg (no shading)4 m at 35 deg, pitch 5 m, profile 15 deg

Accepted: 0.1 to 20 m
Accepted: 1 to 90 °
Accepted: 0.1 to 100 m
Accepted: 1 to 90 °

Results

Long rows on level ground; end effects ignored. For PV a small shaded strip can cut a string's output far more than its area share unless bypass diodes isolate it.

Collector height2.2943m
Clear ground between rows1.7234m
Ground cover ratio L/p0.80000
Profile angle below which shading starts53.088°
Shaded length from the bottom edge2.3107m
Shaded fraction of the collector57.767%
Pitch for no shading at this profile angle11.839m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: PV 2 m at 25 deg, pitch 4.5 m, profile 20 deg (no shading). The inputs, in the units selected above:

InputValue
Collector length up the slope2.0000 m
Collector slope25.000 °
Row pitch (horizontal distance between the same point of adjacent rows)4.5000 m
Profile angle of the sun20.000 °

Applying the formula below gives:

ResultValue
Collector height0.84524 m
Clear ground between rows2.6874 m
Ground cover ratio L/p0.44444
Profile angle below which shading starts17.459 °
Shaded length from the bottom edge0 m
Shaded fraction of the collector0 %
Pitch for no shading at this profile angle4.1349 m

Open this example in the calculator and change any input.

Formula

\(s = L - \frac{p\sin\alpha_p}{\sin(\alpha_p + \beta)}, \quad F_s = \frac{s}{L}\)

\(\tan\alpha_c = \frac{L\sin\beta}{p - L\cos\beta}, \quad p_{min} = \frac{L\sin(\alpha_p + \beta)}{\sin\alpha_p}\)

Variables

Symbol Meaning SI unit
\(L\) Collector length up the slope m
\(\beta\) Collector slope rad
\(p\) Row pitch (horizontal distance between the same point of adjacent rows) m
\(\alpha_p\) Profile angle of the sun rad
\(H\) Collector height m
\(p - L\cos\beta\) Clear ground between rows m
\(GCR\) Ground cover ratio L/p -
\(\alpha_c\) Profile angle below which shading starts rad
\(s\) Shaded length from the bottom edge m
\(F_s\) Shaded fraction of the collector -
\(p_{min}\) Pitch for no shading at this profile angle m

Method and standards

Plane geometry of a shadow cast by one long row on the next.

Where it is used

  • Laying out solar thermal and PV fields.
  • Checking winter shading of existing arrays.

Common mistakes

  • Using solar altitude instead of profile angle for rows not facing the sun's azimuth.
  • Measuring pitch as the clear gap.

Assumptions and limits

  • Level ground, long identical rows.

Questions and answers

Which profile angle should I design for?

Usually the profile angle at 9:00 and 15:00 solar time on the winter solstice, or the lowest angle at which useful energy is still collected.

How do I get the profile angle?

From the incidence-angle calculator for your site, day and hour: tan α_p = tan α_s / cos(γ_s − γ).

What do the defaults represent?

An illustrative case: PV 2 m at 25 deg, pitch 4.5 m, profile 20 deg (no shading). Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Duffie and Beckman, Solar Engineering of Thermal Processes, 4th ed. (Wiley, 2013), sec. 1.9 and Example 1.9.3

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.