FireCADCalc

Flat-Plate Collector Mean Fluid and Plate Temperatures

Mean fluid and mean absorber plate temperatures of a flat-plate collector from inlet temperature, useful gain, heat removal and flow factors and loss coefficient.

Process steam and utilitiesFood, dairy and textile

Inputs

Examples: Selective collector: inlet 60 C, 500 W/m2, FR 0.85, F'' 0.96, UL 4Low flow: inlet 25 C, 300 W/m2, FR 0.6, F'' 0.75, UL 6

Accepted: -23.15 to 226.85 °C
Accepted: 0 to 2,000 W/m²
Accepted: 5 to 100 %
Accepted: 5 to 100 %
Accepted: 0.5 to 30 W/(m²·K)

Results

The mean plate temperature sets the losses, so U_L should be evaluated at T_pm; with a temperature-dependent U_L iterate.

Mean fluid temperature45.833°C
Mean plate temperature58.333°C

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Selective collector: inlet 60 C, 500 W/m2, FR 0.85, F'' 0.96, UL 4. The inputs, in the units selected above:

InputValue
Fluid inlet temperature60.000 °C
Useful gain per unit collector area500.00 W/m²
Heat removal factor85.000 %
Collector flow factor96.000 %
Overall loss coefficient4.0000 W/(m²·K)

Applying the formula below gives:

ResultValue
Mean fluid temperature65.882 °C
Mean plate temperature82.059 °C

Open this example in the calculator and change any input.

Formula

\(T_{fm} = T_i + \frac{Q_u/A_c}{F_RU_L}(1 - F''), \quad T_{pm} = T_i + \frac{Q_u/A_c}{F_RU_L}(1 - F_R)\)

Variables

Symbol Meaning SI unit
\(T_i\) Fluid inlet temperature K
\(q_u\) Useful gain per unit collector area W/m²
\(F_R\) Heat removal factor -
\(F''\) Collector flow factor -
\(U_L\) Overall loss coefficient W/(m²·K)
\(T_{fm}\) Mean fluid temperature K
\(T_{pm}\) Mean plate temperature K

Method and standards

Hottel–Whillier–Bliss mean temperature relations.

Where it is used

  • Iterating U_L with plate temperature.
  • Checking stagnation and boiling risk.

Common mistakes

  • Using the hourly gain in MJ/m² without dividing by 3,600 s.
  • Using F' in place of F''.

Assumptions and limits

  • Steady state; constant U_L.

Questions and answers

Why is the plate hotter than the fluid?

Heat flows from the absorber through the fin and bond into the fluid; the difference is larger with poor fin efficiency or low flow.

Why does it matter?

U_L depends on the plate temperature, and stagnation or boiling checks need it.

What do the defaults represent?

An illustrative case: Selective collector: inlet 60 C, 500 W/m2, FR 0.85, F'' 0.96, UL 4. Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Duffie and Beckman, Solar Engineering of Thermal Processes, 4th ed. (Wiley, 2013), sec. 6.9, eqs. 6.9.2 and 6.9.4 and Example 6.9.1

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.