Worked example
Example: 40 m2 field, glycol 0.5 kg/s, water 0.4 kg/s, eff. 0.6. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Collector area | 40.000 m² |
| Collector F_R U_L | 4.2000 W/(m²·K) |
| Collector F_R(τα)_n | 72.000 % |
| Collector-loop flow | 0.50000 kg/s |
| Collector-loop fluid specific heat | 3.6000 kJ/(kg·K) |
| Tank-side flow | 0.40000 kg/s |
| Tank-side fluid specific heat | 4.1800 kJ/(kg·K) |
| Heat exchanger effectiveness | 60.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Collector-side capacitance rate | 1,800.0 W/K |
| Minimum capacitance rate | 1,672.0 W/K |
| Heat exchanger penalty factor | 93.099 % |
| Intercept with the exchanger | 67.031 % |
| Slope with the exchanger | 3.9101 W/(m²·K) |
Open this example in the calculator and change any input.
Formula
\(\frac{F'_R}{F_R} = \left[1 + \frac{A_cF_RU_L}{(\dot mc_p)_c}\left(\frac{(\dot mc_p)_c}{\varepsilon(\dot mc_p)_{min}} - 1\right)\right]^{-1}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(A_c\) | Collector area | m² |
| \(F_RU_L\) | Collector F_R U_L | W/(m²·K) |
| \(F_R(\tau\alpha)_n\) | Collector F_R(τα)_n | - |
| \(\dot m_c\) | Collector-loop flow | kg/s |
| \(c_{p,c}\) | Collector-loop fluid specific heat | J/(kg·K) |
| \(\dot m_s\) | Tank-side flow | kg/s |
| \(c_{p,s}\) | Tank-side fluid specific heat | J/(kg·K) |
| \(\varepsilon\) | Heat exchanger effectiveness | - |
| \((\dot mc_p)_c\) | Collector-side capacitance rate | W/K |
| \((\dot mc_p)_{min}\) | Minimum capacitance rate | W/K |
| \(F'_R/F_R\) | Heat exchanger penalty factor | - |
| \(F'_R(\tau\alpha)_n\) | Intercept with the exchanger | - |
| \(F'_RU_L\) | Slope with the exchanger | W/(m²·K) |
Method and standards
De Winter's collector–heat exchanger factor.
Where it is used
- Designing glycol solar loops.
- f-chart input F'_R/F_R.
Common mistakes
- Using the tank-side flow as the collector flow.
- Applying the factor twice (once in F_R and again here).
Assumptions and limits
- Steady state, constant effectiveness.
Questions and answers
Why include the heat exchanger at all?
Antifreeze loops protect the collectors from freezing; the price is a higher collector inlet temperature, which this factor expresses.
How can I reduce the penalty?
Larger effectiveness and balanced flows; the penalty also shrinks with a lower collector F_R U_L.
What do the defaults represent?
An illustrative case: 40 m2 field, glycol 0.5 kg/s, water 0.4 kg/s, eff. 0.6. Replace the inputs with your own data.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Duffie and Beckman, Solar Engineering of Thermal Processes, 4th ed. (Wiley, 2013), sec. 10.2, eq. 10.2.3 (de Winter, 1975) and Example 10.2.1