FireCADCalc

Clearness Index and Diffuse Fraction (Erbs Correlations)

Clearness index and the diffuse and beam parts of hourly, daily or monthly average radiation on a horizontal surface by the Erbs, Klein and correlations.

Process steam and utilitiesFood, dairy and textile

Inputs

Examples: Winter day 50 N, 10 December, 2.0 MJ/m2 (overcast)

Accepted: -89 to 89 °
Accepted: 1 to 365
Accepted: 0 to 24 h
Accepted: 0 to 60 MJ/m²

Results

Erbs et al. (1982) correlations from U.S. pyrheliometer data; individual hours and days scatter widely about them.

Extraterrestrial radiation for the period7.6799MJ/m²
Sunset hour angle59.530°
Clearness index0.26042
Diffuse fraction92.721%
Diffuse radiation1.8544MJ/m²
Beam radiation0.14559MJ/m²

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Winter day 50 N, 10 December, 2.0 MJ/m2 (overcast). The inputs, in the units selected above:

InputValue
Radiation periodOne day (daily KT)
Latitude (north positive, south negative)50.000 °
Day of the year (1 = 1 January, 365 = 31 December)344.00 -
Hour midpoint, solar time (hourly basis only)12.000 h
Measured total radiation on a horizontal surface for the period2.0000 MJ/m²
Declination formulaCooper (1969), as in the textbook examples

Applying the formula below gives:

ResultValue
Extraterrestrial radiation for the period7.6799 MJ/m²
Sunset hour angle59.530 °
Clearness index0.26042
Diffuse fraction92.721 %
Diffuse radiation1.8544 MJ/m²
Beam radiation0.14559 MJ/m²

Open this example in the calculator and change any input.

Formula

\(K_T = \frac{H}{H_o}\)

\(\frac{I_d}{I} = 0.9511 - 0.1604k_T + 4.388k_T^2 - 16.638k_T^3 + 12.336k_T^4 \quad (0.22 < k_T \le 0.80)\)

\(\frac{\bar H_d}{\bar H} = 1.391 - 3.560\bar K_T + 4.189\bar K_T^2 - 2.137\bar K_T^3 \quad (\omega_s \le 81.4^\circ)\)

Variables

Symbol Meaning SI unit
\(\text{basis}\) Radiation period -
\(\phi\) Latitude (north positive, south negative) rad
\(n\) Day of the year (1 = 1 January, 365 = 31 December) -
\(t_s\) Hour midpoint, solar time (hourly basis only) s
\(H\) Measured total radiation on a horizontal surface for the period J/m²
\(\delta\text{ formula}\) Declination formula -
\(H_o\) Extraterrestrial radiation for the period J/m²
\(\omega_s\) Sunset hour angle rad
\(K_T\) Clearness index -
\(H_d/H\) Diffuse fraction -
\(H_d\) Diffuse radiation J/m²
\(H_b\) Beam radiation J/m²

Method and standards

Erbs, Klein and (1982) diffuse fraction correlations.

Where it is used

  • Preparing collector-plane radiation for solar thermal and PV design.
  • Checking pyranometer data against diffuse measurements.

Common mistakes

  • Using the hourly correlation on daily data.
  • Applying the monthly correlation to a single day.

Assumptions and limits

  • Correlations from mid-latitude U.S. data; tropical and very polluted sites may differ.

Questions and answers

Why split radiation into beam and diffuse?

Beam radiation on a tilted collector scales with R_b, diffuse with the view of the sky; the split is needed to move horizontal data to the collector plane.

Why does the season matter?

Winter skies (sunset hour angle 81.4° or less) are drier and clearer, so the diffuse fraction is lower at the same clearness.

What do the defaults represent?

An illustrative case: Winter day 50 N, 10 December, 2.0 MJ/m2 (overcast). Replace the inputs with your own data.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Duffie and Beckman, Solar Engineering of Thermal Processes, 4th ed. (Wiley, 2013), secs. 2.10 to 2.12, eqs. 2.10.1, 2.11.1 and 2.12.1 (Erbs, Klein and Duffie, 1982) and Examples 2.11.1, 2.12.1 and 2.15.1

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.