FireCADCalc

Tafel Slope and Exchange Current from Two Cell Points

Tafel constant, slope per decade, charge transfer coefficient and exchange current density from two activation-region voltage and current density points.

Chemical and fertiliser

Inputs

Examples: Illustrative PEM 0.90 V at 10 and 0.82 V at 100 mA/cm2Cooler PEM at 60 C: 0.92 V at 5, 0.84 V at 80 mA/cm2Poor catalyst 0.80/0.70 V

Accepted: 0.0001 to 10,000 mA/cm²
Accepted: 0.1 to 1.5 V
Accepted: 0.0001 to 10,000 mA/cm²
Accepted: 0.1 to 1.5 V
Accepted: 0.5 to 1.5 V
Accepted: -23.15 to 1,026.8 °C

Results

Tafel: V = E − A ln(i/i₀). Two points in the activation-dominated region give A; extrapolating to V = E gives i₀. Ohmic losses between the points inflate A, so use low current densities or iR-corrected voltages.

Tafel constant (V per natural log unit)28.854mV
Tafel slope per decade66.439mV
Charge transfer coefficient RT/(2AF)0.49748
Exchange current density3.0518e-04mA/cm²

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative PEM 0.90 V at 10 and 0.82 V at 100 mA/cm2. The inputs, in the units selected above:

InputValue
First current density10.000 mA/cm²
Cell voltage at i₁0.90000 V
Second current density100.00 mA/cm²
Cell voltage at i₂0.82000 V
Reversible voltage1.1800 V
Cell temperature80.000 °C

Applying the formula below gives:

ResultValue
Tafel constant (V per natural log unit)34.744 mV
Tafel slope per decade80.000 mV
Charge transfer coefficient RT/(2AF)0.43795
Exchange current density0.003162 mA/cm²

Open this example in the calculator and change any input.

Formula

\(A = \frac{V_1 - V_2}{\ln(i_2/i_1)}, \quad i_0 = i_1\exp\left(-\frac{E - V_1}{A}\right), \quad \alpha = \frac{RT}{2AF}\)

Variables

Symbol Meaning SI unit
\(i_1\) First current density A/m²
\(V_1\) Cell voltage at i₁ V
\(i_2\) Second current density A/m²
\(V_2\) Cell voltage at i₂ V
\(E\) Reversible voltage V
\(T\) Cell temperature K
\(A\) Tafel constant (V per natural log unit) V
\(b\) Tafel slope per decade V
\(\alpha\) Charge transfer coefficient RT/(2AF) -
\(i_0\) Exchange current density A/m²

Method and standards

Tafel fit.

Where it is used

  • Fuel cell and electrolyser testing.
  • Catalyst comparison.

Common mistakes

  • Using points where ohmic or mass-transport loss dominates.
  • Mixing natural-log and decade slopes.

Assumptions and limits

  • Activation-controlled region; one electrode dominant.

References

  • Tafel equation fitted to two points

Questions and answers

Why is the exchange current so important?

It sets the activation loss: a cathode with i₀ a thousand times larger loses about 0.2–0.3 V less.

What Tafel slope is typical?

About 60–120 mV per decade for oxygen reduction on platinum, rising with current density.

What do the defaults represent?

Illustrative PEM cell points: 0.90 V at 10 mA/cm² and 0.82 V at 100 mA/cm², with E = 1.18 V at 80 °C.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Larminie and Dicks, Fuel Cell Systems Explained, 2nd ed. (Wiley, 2003), ch. 3

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.