PEM Fuel Cell Exit Air Humidity

Water vapour pressure and relative humidity of the cathode exit air of a PEM fuel cell from air stoichiometry, exit pressure, cell temperature and inlet humidity.

Chemical and fertiliser

Inputs

Examples: Illustrative 70 C, lambda 2, 110 kPa, dry inletPressurised 250 kPa, 80 C, lambda 2Humid inlet 50 % at 25 C, 60 C, lambda 2.5

Accepted: 1.05 to 10
Accepted: 50 to 500 kPa
Accepted: 0.85 to 99.85 °C
Accepted: 0 to 100 %
Accepted: 0.85 to 99.85 °C

Results

All product water leaves as vapour in the cathode air; mole balance per mole of O₂ used gives P_w = (2 + ψλ/y_O₂)/(1 + λ(1 + ψ)/y_O₂)·P_exit, which is Larminie and Dicks' 0.420λ-type formula with y_O₂ = 0.21. Above 100 % the excess condenses (flooding risk); far below, the membrane dries out. Water and steam properties from IAPWS-IF97.

Inlet water-to-dry-air mole ratio0
Exit water vapour partial pressure20.860kPa
Saturation pressure at the cell temperature31.201kPa
Exit relative humidity66.857%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 70 C, lambda 2, 110 kPa, dry inlet. The inputs, in the units selected above:

InputValue
Air stoichiometry2.0000 -
Exit air pressure (absolute)110.00 kPa
Cell (exit air) temperature70.000 °C
Inlet air relative humidity0 %
Inlet air temperature20.000 °C

Applying the formula below gives:

ResultValue
Inlet water-to-dry-air mole ratio0
Exit water vapour partial pressure20.860 kPa
Saturation pressure at the cell temperature31.201 kPa
Exit relative humidity66.857 %

Open this example in the calculator and change any input.

Formula

\(P_w = \frac{2 + \psi\lambda/y_{O_2}}{1 + \lambda(1 + \psi)/y_{O_2}}P_{exit}, \quad \psi = \frac{P_{w,in}}{P_{in} - P_{w,in}}\)

Variables

Symbol Meaning SI unit
\(\lambda\) Air stoichiometry -
\(P_{exit}\) Exit air pressure (absolute) Pa
\(T\) Cell (exit air) temperature K
\(\phi_{in}\) Inlet air relative humidity -
\(T_{in}\) Inlet air temperature K
\(\psi\) Inlet water-to-dry-air mole ratio -
\(P_w\) Exit water vapour partial pressure Pa
\(P_{sat}\) Saturation pressure at the cell temperature Pa
\(\phi\) Exit relative humidity -

Method and standards

Cathode water balance.

Where it is used

  • PEM stack humidification design.
  • Diagnosing drying or flooding.

Common mistakes

  • Ignoring inlet humidity in hot humid climates.
  • Using the stoichiometric air flow.

Assumptions and limits

  • All product water evaporated; uniform exit state.

References

  • Cathode water balance of a PEM fuel cell

Questions and answers

Why does exit humidity matter?

PEM membranes conduct protons only when wet; too dry and resistance rises, too wet and liquid water floods the electrodes.

How can a dry cell be made wetter?

Lower the air flow (stoichiometry), raise the pressure, run cooler, or humidify the inlet air with water recovered from the exhaust.

What do the defaults represent?

An illustrative cell at 70 °C, air at twice stoichiometry, exit at 110 kPa, with dry inlet air.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Larminie and Dicks, Fuel Cell Systems Explained, 2nd ed. (Wiley, 2003), ch. 4

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.