Worked example
Example: Illustrative 50 MW / 4 h battery, 300 cycles. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Power rating | 50.000 MW |
| Storage duration at rated power (hours) | 4.0000 - |
| Energy-related capital cost (currency per kWh) | 250.00 - |
| Power-related capital cost (currency per kW) | 150.00 - |
| Fixed O&M (fraction of capital per year) | 2.0000 % |
| Round-trip efficiency | 86.000 % |
| Usable depth of discharge | 90.000 % |
| Full cycles per year | 300.00 - |
| Life (years) | 15.000 - |
| Discount rate | 7.0000 % |
| Charging electricity price (currency per MWh) | 30.000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Capital cost | 6.3056e+07 |
| Capital recovery factor | 10.979 % |
| Energy discharged per year | 60,000 MWh |
| Capital cost per MWh discharged | 115.39 |
| O&M cost per MWh discharged | 21.019 |
| Charging cost per MWh discharged | 34.884 |
| Levelised cost of storage per MWh | 171.29 |
Open this example in the calculator and change any input.
Formula
\(LCOS = \frac{(CRF + f_{O\&M})C}{E_d} + \frac{c_{ch}}{\eta_{RT}}, \quad C = c_E\frac{Ph}{DoD} + c_PP\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(P\) | Power rating | W |
| \(h\) | Storage duration at rated power (hours) | - |
| \(c_E\) | Energy-related capital cost (currency per kWh) | - |
| \(c_P\) | Power-related capital cost (currency per kW) | - |
| \(f_{O\&M}\) | Fixed O&M (fraction of capital per year) | - |
| \(\eta_{RT}\) | Round-trip efficiency | - |
| \(DoD\) | Usable depth of discharge | - |
| \(N_c\) | Full cycles per year | - |
| \(n\) | Life (years) | - |
| \(i\) | Discount rate | - |
| \(c_{ch}\) | Charging electricity price (currency per MWh) | - |
| \(C\) | Capital cost | - |
| \(CRF\) | Capital recovery factor | - |
| \(E_d\) | Energy discharged per year | J |
| \(c_{cap}\) | Capital cost per MWh discharged | - |
| \(c_{O\&M}\) | O&M cost per MWh discharged | - |
| \(c_{ch}/\eta\) | Charging cost per MWh discharged | - |
| \(LCOS\) | Levelised cost of storage per MWh | - |
Method and standards
Levelised cost of storage.
Where it is used
- Comparing battery, pumped hydro and hydrogen storage.
- Arbitrage and capacity business cases.
Common mistakes
- Dividing by nameplate rather than discharged energy.
- Ignoring the efficiency loss on charging energy.
Assumptions and limits
- Constant cycles and prices; no degradation.
References
- Levelised cost of storage with a capital recovery factor
Questions and answers
What drives storage cost per MWh?
Cycles per year: a 4-hour battery cycled daily spreads its capital over ten times more energy than one used for 30 peaks a year.
Why add the charging price over efficiency?
Every MWh discharged needs 1/η MWh of charging energy; at 86 % efficiency that adds 16 % to the charging price.
What do the defaults represent?
An illustrative 50 MW / 4 h battery at 250 per kWh and 150 per kW, 2 % O&M, 86 % round trip, 90 % depth of discharge, 300 cycles a year, 15 years at 7 % and charging at 30 per MWh.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Gilbert Masters, Renewable and Efficient Electric Power Systems (Wiley, 2004), ch. 5