FireCADCalc

Hydrogen versus Natural Gas Pipeline Energy Capacity

Volume flow and energy throughput of hydrogen in a natural gas pipeline at the same pressure drop, from densities and heating values, with compression power.

Chemical and fertiliser

Inputs

Examples: Illustrative natural gas 17.4 kg/kmol, 39.8 MJ/Nm3Rich gas 19.5, 44Lean gas 16.5, 37

Accepted: 16 to 25 kg/kmol
Accepted: 30 to 50

Results

Equal pressure drop in turbulent flow (same friction factor) gives v ∝ 1/√ρ, so hydrogen flows about 3 times faster by volume while carrying about a third of the energy per Nm³: the energy capacity is about 80–98 % of natural gas. Compression power scales with volume flow, about 3 times more per unit energy. Ideal gases; compressibility and line-pack differences are ignored.

Density ratio0.10338
Volume flow ratio at the same pressure drop3.1101
Hydrogen gross heating value per Nm³ (MJ)12.751
Energy throughput ratio90.129%
Compression power per unit energy delivered, ratio3.4507

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative natural gas 17.4 kg/kmol, 39.8 MJ/Nm3. The inputs, in the units selected above:

InputValue
Natural gas molar mass17.400 kg/kmol
Natural gas gross heating value per Nm³ (MJ)39.800 -

Applying the formula below gives:

ResultValue
Density ratio0.11586
Volume flow ratio at the same pressure drop2.9378
Hydrogen gross heating value per Nm³ (MJ)12.751
Energy throughput ratio94.122 %
Compression power per unit energy delivered, ratio3.1213

Open this example in the calculator and change any input.

Formula

\(\frac{Q_{H_2}}{Q_{NG}} = \sqrt{\frac{\rho_{NG}}{\rho_{H_2}}}, \quad \frac{\dot E_{H_2}}{\dot E_{NG}} = \frac{HHV_{H_2}}{HHV_{NG}}\sqrt{\frac{\rho_{NG}}{\rho_{H_2}}}\)

Variables

Symbol Meaning SI unit
\(M_{NG}\) Natural gas molar mass kg/kmol
\(HHV_{NG}\) Natural gas gross heating value per Nm³ (MJ) -
\(\rho_{H_2}/\rho_{NG}\) Density ratio -
\(Q_{H_2}/Q_{NG}\) Volume flow ratio at the same pressure drop -
\(HHV_{H_2}\) Hydrogen gross heating value per Nm³ (MJ) -
\(\dot E_{H_2}/\dot E_{NG}\) Energy throughput ratio -
\(P_{c,H_2}/P_{c,NG}\) Compression power per unit energy delivered, ratio -

Method and standards

Pipeline energy capacity.

Where it is used

  • Hydrogen network planning.
  • Repurposing natural gas pipelines.

Common mistakes

  • Comparing volume flow instead of energy flow.
  • Ignoring compressor redesign.

Assumptions and limits

  • Same pressures and friction factor; ideal gases.

References

  • Pipeline flow scaling with gas density

Questions and answers

Can a gas pipeline carry as much energy as hydrogen?

Nearly: hydrogen flows about three times faster for the same pressure drop, which almost makes up for its lower energy per cubic metre.

What is the catch?

Compressors must move three times the volume, using more power per unit energy, and steel embrittlement must be checked.

What do the defaults represent?

An illustrative natural gas of molar mass 17.4 kg/kmol and 39.8 MJ/Nm³.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Larminie and Dicks, Fuel Cell Systems Explained, 2nd ed. (Wiley, 2003), ch. 8

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.