FireCADCalc

Hydrogen Fleet Demand, Electrolyser Size and Storage

Daily hydrogen demand of a fuel cell vehicle fleet, the electrolyser power to make it in the available hours, and the storage to cover days without production.

Thermal power plant

Inputs

Examples: Illustrative 20 buses, 250 kmTrucks 10 at 400 kmCars 100 at 50 km

Accepted: 1 to 100,000
Accepted: 1 to 2,000 km
Accepted: 0.3 to 20
Accepted: 9.7222 to 111.11 kWh/kg
Accepted: 1 to 24 h
Accepted: 0 to 30

Results

Daily hydrogen = N·d·c/100; electrolyser power = m_d·e/t_op. Compression, dispensing losses and refuelling peaks need extra storage and margin.

Hydrogen per day50.000kg
Electrolyser power0.12083MW
Electricity per day2.9000MWh
Hydrogen storage150.00kg

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 20 buses, 250 km. The inputs, in the units selected above:

InputValue
Vehicles20.000 -
Distance per vehicle per day250.00 km
Hydrogen use per 100 km (kg)8.0000 -
Electrolyser system specific energy55.000 kWh/kg
Electrolyser operating hours per day20.000 h
Days of storage2.0000 -

Applying the formula below gives:

ResultValue
Hydrogen per day400.00 kg
Electrolyser power1.1000 MW
Electricity per day22.000 MWh
Hydrogen storage800.00 kg

Open this example in the calculator and change any input.

Formula

\(m_d = \frac{Ndc}{100}, \quad P_e = \frac{m_de}{t_{op}}\)

Variables

Symbol Meaning SI unit
\(N\) Vehicles -
\(d\) Distance per vehicle per day m
\(c\) Hydrogen use per 100 km (kg) -
\(e\) Electrolyser system specific energy J/kg
\(t_{op}\) Electrolyser operating hours per day s
\(t_s\) Days of storage -
\(m_d\) Hydrogen per day kg
\(P_e\) Electrolyser power W
\(E_d\) Electricity per day J
\(m_s\) Hydrogen storage kg

Method and standards

Fleet hydrogen balance.

Where it is used

  • Bus and truck depot hydrogen projects.
  • Refuelling station sizing.

Common mistakes

  • Forgetting compression energy.
  • Sizing storage without refuelling peaks.

Assumptions and limits

  • Daily average demand.

References

  • Fleet hydrogen balance

Questions and answers

How much hydrogen does a bus use?

About 7–10 kg per 100 km for a 12 m fuel cell bus, so 250 km a day needs about 20 kg.

Why run the electrolyser long hours?

A high utilisation spreads its capital cost; storage then buffers the difference between steady production and refuelling peaks.

What do the defaults represent?

An illustrative 20 buses running 250 km a day at 8 kg per 100 km, an electrolyser at 55 kWh/kg running 20 h a day and two days of storage.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Larminie and Dicks, Fuel Cell Systems Explained, 2nd ed. (Wiley, 2003), ch. 8

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.