FireCADCalc

Water Electrolyser Hydrogen Production and Specific Energy

Hydrogen and oxygen production, specific energy in kWh per kg and per Nm³, efficiency, water use and heat of a water electrolyser from power and cell voltage.

Thermal power plantChemical and fertiliser

Inputs

Examples: Illustrative 5 MW at 1.9 VAlkaline 20 MW at 2.0 V, 97 %Solid oxide 1 MW at 1.3 V

Accepted: 1E-6 to 10,000 MW
Accepted: 1.2 to 3 V
Accepted: 50 to 100 %

Results

ṅ_H₂ = η_F P/(2FV_c). Thermoneutral voltage 1.481 V (HHV); above it the cell makes heat, below it the cell needs heat. Plant figures add rectifier, compression and auxiliary loads (typically 10–20 % more).

Hydrogen production28.641kg/h
Hydrogen production (normal volume)318.44Nm³/h
Specific energy (stack)34.915kWh/kg
Specific energy per Nm³ (kWh/Nm³)3.1404
Efficiency on the higher heating value112.79%
Efficiency on the lower heating value95.429%
Water consumed (stoichiometric)255.94kg/h
Oxygen produced227.30kg/h
Heat to remove (above the thermoneutral voltage)-127.88kW

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 5 MW at 1.9 V. The inputs, in the units selected above:

InputValue
Electrical power to the stacks5.0000 MW
Cell voltage1.9000 V
Faraday (current) efficiency98.000 %

Applying the formula below gives:

ResultValue
Hydrogen production96.994 kg/h
Hydrogen production (normal volume)1,078.4 Nm³/h
Specific energy (stack)51.550 kWh/kg
Specific energy per Nm³ (kWh/Nm³)4.6366
Efficiency on the higher heating value76.391 %
Efficiency on the lower heating value64.634 %
Water consumed (stoichiometric)866.74 kg/h
Oxygen produced769.74 kg/h
Heat to remove (above the thermoneutral voltage)1,180.4 kW

Open this example in the calculator and change any input.

Formula

\(\dot n_{H_2} = \frac{\eta_FP}{2FV_c}, \quad \eta_{HHV} = \eta_F\frac{1.481}{V_c}, \quad e = \frac{P}{\dot m_{H_2}}\)

Variables

Symbol Meaning SI unit
\(P\) Electrical power to the stacks W
\(V_c\) Cell voltage V
\(\eta_F\) Faraday (current) efficiency -
\(\dot m_{H_2}\) Hydrogen production kg/s
\(\dot V_{H_2}\) Hydrogen production (normal volume) Nm³/s
\(e\) Specific energy (stack) J/kg
\(e_V\) Specific energy per Nm³ (kWh/Nm³) -
\(\eta_{HHV}\) Efficiency on the higher heating value -
\(\eta_{LHV}\) Efficiency on the lower heating value -
\(\dot m_{H_2O}\) Water consumed (stoichiometric) kg/s
\(\dot m_{O_2}\) Oxygen produced kg/s
\(\dot Q\) Heat to remove (above the thermoneutral voltage) W

Method and standards

Faraday's law for electrolysis.

Where it is used

  • Green hydrogen project sizing.
  • Comparing electrolyser offers.

Common mistakes

  • Mixing stack and system specific energy.
  • Quoting efficiency without saying HHV or LHV.

Assumptions and limits

  • Steady operation; Faraday losses as a single efficiency.

References

  • Faraday's law and thermoneutral voltage of water electrolysis

Questions and answers

How much electricity does 1 kg of hydrogen need?

At least 39.4 kWh (its higher heating value); real stacks at 1.8–2.0 V use about 48–54 kWh/kg, and whole plants 50–60 kWh/kg.

How much water is needed?

Nine kilograms per kilogram of hydrogen by stoichiometry; treatment rejects mean that 15–20 kg of raw water is typical.

What do the defaults represent?

An illustrative 5 MW electrolyser at 1.9 V per cell and 98 % Faraday efficiency.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Larminie and Dicks, Fuel Cell Systems Explained, 2nd ed. (Wiley, 2003), ch. 8

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.