FireCADCalc

Wind Turbine Power, Betz Limit and Annual Energy

Power in the wind through a rotor, the turbine output at a power coefficient (Betz limit 16/27), and annual energy from a capacity factor.

Inputs

Examples: 100 m rotor at 9 m/sSmall turbine 10 m at 6 m/s

Results

Annual energy here scales the output at this wind speed by the capacity factor; a proper estimate uses the power curve and the site's wind distribution.

Swept area78.540m²
Power in the wind ½ρAv³0.010179MW
Betz-limit power (16/27)0.006032MW
Turbine output at C_p0.003563MW
Annual energy at the capacity factor6.8658MWh

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 100 m rotor at 9 m/s. The inputs, in the units selected above:

InputValue
Air density1.2250 kg/m³
Rotor diameter100.00 m
Wind speed at hub height9.0000 m/s
Power coefficient (turbine and drive)42.000 %
Capacity factor (for annual energy)30.000 %

Applying the formula below gives:

ResultValue
Swept area7,854.0 m²
Power in the wind ½ρAv³3.5069 MW
Betz-limit power (16/27)2.0782 MW
Turbine output at C_p1.4729 MW
Annual energy at the capacity factor3,870.8 MWh

Open this example in the calculator and change any input.

Formula

\(P = \frac{1}{2}\rho A v^3 C_p, \quad C_{p,max} = \frac{16}{27}\)

Variables

Symbol Meaning SI unit
\(\rho\) Air density kg/m³
\(D\) Rotor diameter m
\(v\) Wind speed at hub height m/s
\(C_p\) Power coefficient (turbine and drive) -
\(CF\) Capacity factor (for annual energy) -
\(A\) Swept area m²
\(P_w\) Power in the wind ½ρAv³ W
\(P_{Betz}\) Betz-limit power (16/27) W
\(P\) Turbine output at C_p W
\(E\) Annual energy at the capacity factor J

Method and standards

Actuator disc.

Where it is used

  • Captive wind projects.
  • Teaching and examinations.

Common mistakes

  • Mean speed cubed instead of the mean of cubes.
  • Ground-level wind speed.

Assumptions and limits

  • Annual energy = P × CF × 8 760 h (a 365-day year): the output at one wind speed scaled by a capacity factor, not an integral over a power curve and wind distribution. The Weibull wind energy calculator does that, with a 365.25-day year, so its CF means the long-term average output over rated power.

  • Steady uniform wind.

References

  • P = ½ρAv³C_p; Betz (1920) limit C_p ≤ 16/27

Questions and answers

100 m rotor at 9 m/s, C_p 0.42?

About 1.47 MW.

Why does wind speed matter so much?

Power goes with the cube: 10 % more wind gives 33 % more power.

Betz limit?

No turbine can extract more than 16/27 (59.3 %) of the wind's power.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.