FireCADCalc

Wind Energy from a Weibull Wind Distribution

Annual energy and capacity factor of a wind turbine from mean wind speed corrected to hub height, a Weibull shape factor and a simple power curve.

Process steam and utilitiesSugar mill and cogenerationChemical and fertiliser

Inputs

Examples: 2 MW at 100 m, 6 m/s at 10 mCoastal 3 MW at 120 m, 7 m/s at 50 m, k 2.4

Results

Simplified power curve: cubic between cut-in and rated speed, rated output to cut-out. Use the maker's power curve for a bankable estimate. Weibull k ≈ 2 (Rayleigh) for most inland sites; air density 1.225 kg/m³.

Mean speed at hub height7.7076m/s
Weibull scale at hub height8.6946m/s
Mean wind power density456.13W/m²
Capacity factor34.972%
Annual energy9,196.9MWh

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 2 MW at 100 m, 6 m/s at 10 m. The inputs, in the units selected above:

InputValue
Mean wind speed at the reference height6.0000 m/s
Reference height10.000 m
Hub height100.00 m
Shear exponent0.14000 -
Weibull shape factor2.0000 -
Rated power2,000.0 kW
Cut-in speed3.0000 m/s
Rated speed12.000 m/s
Cut-out speed25.000 m/s
Availability and other losses10.000 %

Applying the formula below gives:

ResultValue
Mean speed at hub height8.2823 m/s
Weibull scale at hub height9.3456 m/s
Mean wind power density664.60 W/m²
Capacity factor36.018 %
Annual energy6,314.7 MWh

Open this example in the calculator and change any input.

Formula

\(\bar v_h = \bar v_r\left(\frac{z_h}{z_r}\right)^\alpha, \quad c = \frac{\bar v_h}{\Gamma(1 + 1/k)}, \quad CF = (1 - f_l)\int P(v)f(v)\,dv / P_r, \quad E = CF\,P_r\,t_a, \quad \frac PA = \frac12\rho_0 c^3\,\Gamma\left(1 + \frac3k\right)\)

Variables

Symbol Meaning SI unit
\(\bar v_r\) Mean wind speed at the reference height m/s
\(z_r\) Reference height m
\(z_h\) Hub height m
\(\alpha\) Shear exponent -
\(k\) Weibull shape factor -
\(P_r\) Rated power W
\(v_{in}\) Cut-in speed m/s
\(v_r\) Rated speed m/s
\(v_{out}\) Cut-out speed m/s
\(f_l\) Availability and other losses -
\(\bar v_h\) Mean speed at hub height m/s
\(c\) Weibull scale at hub height m/s
\(P/A\) Mean wind power density W/m²
\(CF\) Capacity factor -
\(E\) Annual energy J
\(t_a\) One year, 365.25 days (8 766 h) s
\(\rho_0\) Air density, fixed at 1.225 kg/m³ kg/m³

Method and standards

Weibull integration.

Where it is used

  • Wind farm screening for captive power.
  • Comparing sites.

Common mistakes

  • Using the mean speed in the cube.
  • Ignoring shear to hub height.

Assumptions and limits

  • The year is 365.25 days (8 766 h), allowing for leap years; calculators that use 8 760 h give energy about 0.07 % lower.

  • The power density uses a fixed air density of 1.225 kg/m³ (sea level, 15 °C); scale it by the site density for altitude or temperature. The capacity factor comes from the normalised power curve and does not depend on density.

  • Weibull distribution; simplified power curve.

References

  • Weibull wind statistics and power-law shear (Manwell, McGowan and Rogers, Wind Energy Explained, 2nd ed., ch. 2)

Questions and answers

Why not use the mean wind speed directly?

Power varies with v³; the spread of speeds about the mean carries much more energy than the mean alone suggests.

Why correct to hub height?

Wind speed rises with height; at 100 m it is often 35–40 % higher than at a 10 m met mast.

What do the defaults represent?

A 2 MW turbine on a 100 m tower at a site with 6 m/s mean at 10 m.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.