Worked example
Example: Gas engine CHP. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Fuel input per year | 300,000 GJ |
| Electricity produced per year | 105,000 GJ |
| Useful heat per year | 135,000 GJ |
| Reference efficiency for separate power | 52.500 % |
| Reference efficiency for separate heat | 90.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Electrical efficiency | 35.000 % |
| Heat efficiency | 45.000 % |
| Overall efficiency | 80.000 % |
| Primary energy saving | 14.286 % |
Open this example in the calculator and change any input.
Formula
\(PES = 1 - \frac{1}{\frac{\eta_H}{\eta_{ref,H}} + \frac{\eta_E}{\eta_{ref,E}}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(F\) | Fuel input per year | J |
| \(E\) | Electricity produced per year | J |
| \(H\) | Useful heat per year | J |
| \(\eta_{ref,E}\) | Reference efficiency for separate power | - |
| \(\eta_{ref,H}\) | Reference efficiency for separate heat | - |
| \(\eta_E\) | Electrical efficiency | - |
| \(\eta_H\) | Heat efficiency | - |
| \(\eta_o\) | Overall efficiency | - |
| \(PES\) | Primary energy saving | - |
Method and standards
EU method.
Where it is used
- Cogeneration in sugar, paper and process plants.
- Policy and incentive claims.
Common mistakes
- Gross instead of net electricity.
- Including heat that is not useful.
Assumptions and limits
- Annual totals.
- The regulatory calculation applies correction factors to η_ref,E (average climate, avoided grid losses) and puts all efficiencies on the net calorific value of the fuel; enter the corrected reference values and NCV-based energies, or the PES here may differ from the regulatory one.
References
- PES = 1 − 1/(η_H/η_ref,H + η_E/η_ref,E) (EU Directive 2012/27/EU, Annex II)
Questions and answers
35 % electrical and 45 % heat efficiency?
PES about 14.3 % against references 52.5 % and 90 %.
Sugar mill cogeneration?
Back-pressure turbines give high heat efficiency and strong PES.
Reference values?
Your regulator's harmonised values for the fuel and year of build.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.