Worked example
Example: 45.2 g against 0.85 m3, 60 °C stack. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Water collected (impingers plus silica gel) | 45.200 g |
| Dry gas metered | 850.00 L |
| Dry gas meter calibration factor | 1.0000 - |
| Meter temperature | 25.000 °C |
| Meter pressure (absolute) | 100.50 kPa |
| Stack temperature | 60.000 °C |
| Stack pressure (absolute) | 100.00 kPa |
Applying the formula below gives:
| Result | Value |
|---|---|
| Water vapour at 20 °C, 101.325 kPa | 60.355 L |
| Dry gas at 20 °C, 101.325 kPa | 828.94 L |
| Moisture fraction measured | 6.7868 % |
| Moisture at saturation (stack conditions) | 19.946 % |
| Moisture to report (the lower) | 6.7868 % |
Open this example in the calculator and change any input.
Formula
\(V_{w,std} = \frac{m_w}{M_w}\frac{RT_{std}}{p_{std}}, \quad V_{m,std} = V_mY\frac{T_{std}}{T_m}\frac{p_m}{p_{std}}, \quad B_{ws} = \frac{V_{w,std}}{V_{w,std} + V_{m,std}}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(m_w\) | Water collected (impingers plus silica gel) | kg |
| \(V_m\) | Dry gas metered | m³ |
| \(Y\) | Dry gas meter calibration factor | - |
| \(T_m\) | Meter temperature | K |
| \(p_m\) | Meter pressure (absolute) | Pa |
| \(T_s\) | Stack temperature | K |
| \(p_s\) | Stack pressure (absolute) | Pa |
| \(V_{w,std}\) | Water vapour at 20 °C, 101.325 kPa | m³ |
| \(V_{m,std}\) | Dry gas at 20 °C, 101.325 kPa | m³ |
| \(B_{ws}\) | Moisture fraction measured | - |
| \(B_{ws,sat}\) | Moisture at saturation (stack conditions) | - |
| \(B_{ws,rep}\) | Moisture to report (the lower) | - |
| \(M_w\) | Molar mass of water, 18.015 | kg/kmol |
| \(R\) | Universal gas constant, 8.314 462 618 | J/(mol·K) |
| \(T_{std}, p_{std}\) | Standard conditions, 293.15 K and 101 325 Pa | K, Pa |
Method and standards
EPA Method 4 calculations in SI.
Where it is used
- Stack testing and emission reporting.
- Wet–dry concentration conversion.
Common mistakes
- Leaving out the silica gel gain.
- Using gauge meter pressure.
Assumptions and limits
- Ideal gas; standard conditions 20 °C, 101.325 kPa.
References
- US EPA Method 4
- 40 CFR Part 60 Appendix A-3 (determination of moisture content in stack gases)
- standard conditions 20 °C and 101.325 kPa; IAPWS-IF97 saturation pressure
Questions and answers
Why compare with saturation?
Droplets in a wet stack add water the gas does not actually carry as vapour; EPA requires the lower of the measured and saturation values.
Where does the water come from?
Impinger liquid gain plus the silica gel weight gain.
What do the defaults give?
45.2 g of water against 0.85 m³ of dry gas: about 6.8 % moisture, well below saturation at 60 °C.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.