FireCADCalc

Gravity Settling Chamber: Efficiency and Cut Size

Stokes settling velocity of a particle, collection efficiency of a gravity settling chamber in laminar flow, and the smallest particle collected completely.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolChemical and fertiliserPulp and paper

Inputs

Examples: 5 m³/s, 10 × 4 m, 50 µm dustBagasse ash drop-out box, 100 µm

1.2 kg/m³ for air at 20 °C; about 0.6 for flue gas at 300 °C.

Results

Plug-flow (laminar) model η = v_tLW/Q. Settling chambers are only useful for coarse particles (above about 50 µm) as pre-cleaners.

Settling velocity0.17335m/s
Collection efficiency for d_p34.670%
Smallest particle collected completely169.83µm
Particle Reynolds number (check < 1)0.94554

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 5 m³/s, 10 × 4 m, 50 µm dust. The inputs, in the units selected above:

InputValue
Gas flow18,000 m³/h
Chamber length10.000 m
Chamber width4.0000 m
Particle diameter50.000 µm
Particle density2,000.0 kg/m³
Gas viscosity1.8500e-05 Pa·s
Gas density (for the Reynolds check)1.2000 kg/m³

Applying the formula below gives:

ResultValue
Settling velocity0.14725 m/s
Collection efficiency for d_p100.00 %
Smallest particle collected completely46.068 µm
Particle Reynolds number (check < 1)0.47756

Open this example in the calculator and change any input.

Formula

\(v_t = \frac{g\rho_pd_p^2}{18\mu}, \quad \eta = \frac{v_tLW}{Q}, \quad d_{100} = \sqrt{\frac{18\mu Q}{g\rho_pLW}}, \quad Re_p = \frac{\rho_g v_t d_p}{\mu}\)

Variables

Symbol Meaning SI unit
\(Q\) Gas flow m³/s
\(L\) Chamber length m
\(W\) Chamber width m
\(d_p\) Particle diameter m
\(\rho_p\) Particle density kg/m³
\(\mu\) Gas viscosity Pa·s
\(\rho_g\) Gas density (for the Reynolds check) kg/m³
\(g\) Standard gravity, 9.806 65 m/s²
\(v_t\) Settling velocity m/s
\(\eta\) Collection efficiency for d_p -
\(d_{100}\) Smallest particle collected completely m
\(Re_p\) Particle Reynolds number (check < 1) -

Method and standards

Stokes law and plug flow.

Where it is used

  • Ash and bagasse fly-ash pre-collection.
  • Drop-out boxes ahead of fabric filters.

Common mistakes

  • Using it outside Stokes' range.
  • Ignoring re-entrainment.

Assumptions and limits

  • Laminar flow; Stokes regime (Re_p below 1; the page warns above it).
  • The gas density enters only the Reynolds check; enter the density at the chamber temperature for hot flue gas.

References

  • Laminar settling chamber model (de Nevers, Air Pollution Control Engineering, 2nd ed. (McGraw-Hill, 2000), ch. 9)

Questions and answers

Why is the height not in the formula?

A taller chamber slows the gas but particles must fall further; the two effects cancel.

How can efficiency be raised?

Larger floor area (L × W) or trays that cut the settling height.

What do the defaults represent?

5 m³/s through a 10 × 4 m chamber with 50 µm mineral dust.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.