Worked example
Example: 5 m³/s, 10 × 4 m, 50 µm dust. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Gas flow | 18,000 m³/h |
| Chamber length | 10.000 m |
| Chamber width | 4.0000 m |
| Particle diameter | 50.000 µm |
| Particle density | 2,000.0 kg/m³ |
| Gas viscosity | 1.8500e-05 Pa·s |
| Gas density (for the Reynolds check) | 1.2000 kg/m³ |
Applying the formula below gives:
| Result | Value |
|---|---|
| Settling velocity | 0.14725 m/s |
| Collection efficiency for d_p | 100.00 % |
| Smallest particle collected completely | 46.068 µm |
| Particle Reynolds number (check < 1) | 0.47756 |
Open this example in the calculator and change any input.
Formula
\(v_t = \frac{g\rho_pd_p^2}{18\mu}, \quad \eta = \frac{v_tLW}{Q}, \quad d_{100} = \sqrt{\frac{18\mu Q}{g\rho_pLW}}, \quad Re_p = \frac{\rho_g v_t d_p}{\mu}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q\) | Gas flow | m³/s |
| \(L\) | Chamber length | m |
| \(W\) | Chamber width | m |
| \(d_p\) | Particle diameter | m |
| \(\rho_p\) | Particle density | kg/m³ |
| \(\mu\) | Gas viscosity | Pa·s |
| \(\rho_g\) | Gas density (for the Reynolds check) | kg/m³ |
| \(g\) | Standard gravity, 9.806 65 | m/s² |
| \(v_t\) | Settling velocity | m/s |
| \(\eta\) | Collection efficiency for d_p | - |
| \(d_{100}\) | Smallest particle collected completely | m |
| \(Re_p\) | Particle Reynolds number (check < 1) | - |
Method and standards
Stokes law and plug flow.
Where it is used
- Ash and bagasse fly-ash pre-collection.
- Drop-out boxes ahead of fabric filters.
Common mistakes
- Using it outside Stokes' range.
- Ignoring re-entrainment.
Assumptions and limits
- Laminar flow; Stokes regime (Re_p below 1; the page warns above it).
- The gas density enters only the Reynolds check; enter the density at the chamber temperature for hot flue gas.
References
- Laminar settling chamber model (de Nevers, Air Pollution Control Engineering, 2nd ed. (McGraw-Hill, 2000), ch. 9)
Questions and answers
Why is the height not in the formula?
A taller chamber slows the gas but particles must fall further; the two effects cancel.
How can efficiency be raised?
Larger floor area (L × W) or trays that cut the settling height.
What do the defaults represent?
5 m³/s through a 10 × 4 m chamber with 50 µm mineral dust.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.