Worked example
Example: Cyclone then ESP. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Collector 1 efficiency | 85.000 % |
| Collector 2 efficiency | 99.500 % |
| Collector 3 efficiency (0 if none) | 0 % |
| Inlet dust concentration | 40,000 mg/Nm³ |
| Gas flow (normal) | 150,000 Nm³/h |
Applying the formula below gives:
| Result | Value |
|---|---|
| Overall efficiency | 99.925 % |
| Outlet concentration | 30.000 mg/Nm³ |
| Dust captured | 5.9955 t/h |
Open this example in the calculator and change any input.
Formula
\(\eta_o = 1 - \prod_i (1 - \eta_i), \quad C_{out} = C_{in}\prod_i(1 - \eta_i)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\eta_1\) | Collector 1 efficiency | - |
| \(\eta_2\) | Collector 2 efficiency | - |
| \(\eta_3\) | Collector 3 efficiency (0 if none) | - |
| \(C_{in}\) | Inlet dust concentration | kg/m³ |
| \(\dot V_N\) | Gas flow (normal) | Nm³/s |
| \(\eta_o\) | Overall efficiency | - |
| \(C_{out}\) | Outlet concentration | kg/m³ |
| \(\dot m_c\) | Dust captured | kg/s |
Method and standards
Penetration.
Where it is used
- Boiler dust collection trains.
- Compliance checks.
Common mistakes
- Adding efficiencies.
- Stage efficiency measured on a different dust.
Assumptions and limits
- Independent stages: each η_i is the efficiency for the dust that actually reaches that stage. A collector after a cyclone sees finer dust, so its catalogue efficiency (quoted for the raw dust) overstates the overall result.
References
- Penetrations multiply: 1 − η_o = Π(1 − η_i)
Questions and answers
85 % cyclone then a 99.5 % ESP on 40 g/Nm³?
Overall 99.925 %: 30 mg/Nm³ out.
Why not add efficiencies?
Each stage only sees what the previous one let through.
Does the ESP keep 99.5 %?
Not always: finer dust after a cyclone can lower it.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.