FireCADCalc

Induction Motor Torque–Slip from the Equivalent Circuit

Torque, current and power factor of an induction motor at a slip, with breakdown and starting torque, from the per-phase equivalent circuit.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: 4-pole 415 V at 3 % slip6-pole, 5 % slip

Results

Standard per-phase equivalent circuit with core loss neglected; torque from the Thevenin form. Parameters come from no-load and locked-rotor tests.

Torque at the slip116.33N·m
Stator current30.039A
Power factor0.87138
Breakdown torque372.32N·m
Slip at breakdown20.846%
Starting torque161.97N·m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 4-pole 415 V at 3 % slip. The inputs, in the units selected above:

InputValue
Line voltage (parameters per phase of the star equivalent, V/√3)415.00 V
Frequency50.000 Hz
Poles4.0000 -
Stator resistance per phase0.20000 Ω
Stator leakage reactance0.60000 Ω
Rotor resistance referred to stator0.25000 Ω
Rotor leakage reactance referred0.60000 Ω
Magnetising reactance20.000 Ω
Slip3.0000 %

Applying the formula below gives:

ResultValue
Torque at the slip116.33 N·m
Stator current30.039 A
Power factor0.87138
Breakdown torque372.32 N·m
Slip at breakdown20.846 %
Starting torque161.97 N·m

Open this example in the calculator and change any input.

Formula

\(T = \frac{3V_{th}^2R'_2/s}{\omega_s\left[(R_{th} + R'_2/s)^2 + (X_{th} + X'_2)^2\right]}, \quad s_{max} = \frac{R'_2}{\sqrt{R_{th}^2 + (X_{th} + X'_2)^2}}\)

Variables

Symbol Meaning SI unit
\(V\) Line voltage (parameters per phase of the star equivalent, V/√3) V
\(f\) Frequency 1/s
\(p\) Poles -
\(R_1\) Stator resistance per phase Ω
\(X_1\) Stator leakage reactance Ω
\(R'_2\) Rotor resistance referred to stator Ω
\(X'_2\) Rotor leakage reactance referred Ω
\(X_m\) Magnetising reactance Ω
\(s\) Slip -
\(T\) Torque at the slip N·m
\(I_1\) Stator current A
\(\cos\phi\) Power factor -
\(T_{max}\) Breakdown torque N·m
\(s_{max}\) Slip at breakdown -
\(T_{st}\) Starting torque N·m

Method and standards

Equivalent circuit.

Where it is used

  • Motor selection for high-inertia starts.
  • Teaching motor behaviour.

Common mistakes

  • Line voltage in per-phase formulas.
  • Rotor values not referred to the stator.

Assumptions and limits

  • Constant parameters (no saturation or deep-bar effect).
  • Parameters per phase of the star equivalent with phase voltage V/√3; convert delta-connected test data to star first (divide impedances by 3).
  • Poles an even whole number. When the breakdown slip exceeds 1 it is shown as 100 % and a note explains that T_max is not reached in motoring.

References

  • Chapman
  • Electric Machinery Fundamentals
  • 5th ed. (McGraw-Hill, 2012)
  • ch. 6 (induction motor equivalent circuit and torque–speed characteristic)

Questions and answers

What sets breakdown torque?

Mostly the leakage reactances; rotor resistance changes the slip at which it occurs, not its value.

Why add rotor resistance for starting?

It moves breakdown towards standstill, raising starting torque (slip-ring motors, deep-bar rotors).

What do the defaults represent?

A 4-pole, 415 V motor with typical small-motor parameters at 3 % slip.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.