FireCADCalc

Wheatstone Bridge: Unknown Resistance and Output Voltage

Unknown resistance at balance of a Wheatstone bridge from the three known arms, and the bridge output voltage for any fourth arm and supply.

Inputs

Examples: 1 k, 2 k, 500 Ω, Rx 1 010 Ω, 10 VPt100 bridge: 100, 100, 100, 138.5 Ω, 5 V120 Ω strain gauge +0.24 Ω, 10 V

Results

Fourth arm at balance R₂ R₃ / R₁120.00Ω
Bridge output voltage4.9950mV
Deviation of R_x from balance0.20000%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 1 k, 2 k, 500 Ω, Rx 1 010 Ω, 10 V. The inputs, in the units selected above:

InputValue
Arm R₁ (top left)1,000.0 Ω
Arm R₂ (bottom left)2,000.0 Ω
Arm R₃ (top right)500.00 Ω
Fourth arm, actual value (bottom right)1,010.0 Ω
Supply voltage10.000 V

Applying the formula below gives:

ResultValue
Fourth arm at balance R₂ R₃ / R₁1,000.0 Ω
Bridge output voltage22.075 mV
Deviation of R_x from balance1.0000 %

Open this example in the calculator and change any input.

Formula

\(R_{x,bal} = \frac{R_2 R_3}{R_1}, \quad V_o = V_s \left(\frac{R_x}{R_3 + R_x} - \frac{R_2}{R_1 + R_2}\right)\)

Variables

Symbol Meaning SI unit
\(R_1\) Arm R₁ (top left) Ω
\(R_2\) Arm R₂ (bottom left) Ω
\(R_3\) Arm R₃ (top right) Ω
\(R_x\) Fourth arm, actual value (bottom right) Ω
\(V_s\) Supply voltage V
\(R_{x,bal}\) Fourth arm at balance R₂ R₃ / R₁ Ω
\(V_o\) Bridge output voltage V
\(\delta\) Deviation of R_x from balance -

Method and standards

Two voltage dividers compared.

Where it is used

  • RTD and strain gauge circuits.
  • Laboratory resistance measurement.

Common mistakes

  • Arms in the wrong position.
  • Lead resistance ignored.

Assumptions and limits

  • High-impedance detector.

References

  • Wheatstone bridge balance R₁/R₂ = R₃/R_x

Questions and answers

What balances 1000, 2000 and 500 Ω?

R_x = 2000 × 500 / 1000 = 1000 Ω.

What output for R_x = 1010 Ω at 10 V?

22.1 mV.

Why use a bridge?

It measures small changes of resistance as a voltage around zero.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.