FireCADCalc

Closed Traverse Angle Misclosure and Balancing

Angular misclosure of a closed traverse from the sum of its interior angles, the correction per angle and the allowable misclosure for the order of survey.

Inputs

Examples: Illustrative 5 sides, +25 secondsQuadrilateral, -18 secondsNine sides, 1 minute over

Accepted: 3 to 100
Accepted: 0 to 11,459 °
Accepted: 1 to 120

Results

Interior angles of a closed polygon sum to (n − 2)180°. The misclosure is spread equally over the angles (they were measured with equal care), rounding so the corrections sum exactly to the misclosure. Allowable misclosure is usually K√n, with K from the job specification or accuracy standard (for example 10–30″ for engineering traverses).

Correct sum1,260.0°
Misclosure (arc seconds)60.000
Correction per angle (arc seconds)-6.6667
Allowable misclosure (arc seconds)45.000
Ratio to allowable1.3333

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 5 sides, +25 seconds. The inputs, in the units selected above:

InputValue
Number of sides (angles)5.0000 -
Sum of observed interior angles540.01 °
Allowable constant (arc seconds × √n)15.000 -

Applying the formula below gives:

ResultValue
Correct sum540.00 °
Misclosure (arc seconds)25.000
Correction per angle (arc seconds)-5.0000
Allowable misclosure (arc seconds)33.541
Ratio to allowable0.74536

Open this example in the calculator and change any input.

Formula

\(e = \Sigma\beta - (n - 2)180^\circ, \quad c = -\frac en, \quad e_{allow} = K\sqrt n\)

Variables

Symbol Meaning SI unit
\(n\) Number of sides (angles) -
\(\Sigma\beta\) Sum of observed interior angles rad
\(K\) Allowable constant (arc seconds × √n) -
\((n - 2)180^\circ\) Correct sum rad
\(e\) Misclosure (arc seconds) -
\(c\) Correction per angle (arc seconds) -
\(K\sqrt n\) Allowable misclosure (arc seconds) -
\(|e|/K\sqrt n\) Ratio to allowable -

Method and standards

Angle balancing.

Where it is used

  • Closed traverse computation.
  • Field checks before leaving a station.

Common mistakes

  • Mixing interior and exterior angles.
  • Not checking for a blunder before balancing.

Assumptions and limits

  • Equal weight angles; closed polygon.

References

  • Angular misclosure and balancing

Questions and answers

Why spread the error equally?

Each angle was measured with the same equipment and care, so each is equally likely to be in error.

What if the misclosure exceeds the allowable?

Re-observe; it usually means a blunder in one angle rather than random error.

What do the defaults represent?

An illustrative five-sided traverse whose interior angles sum to 540°00′25″, with 15″√n allowed.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Ghilani and Wolf, Elementary Surveying: An Introduction to Geomatics, 13th ed. (Pearson, 2012)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.