FireCADCalc

Transverse Mercator (UTM) Point Scale Factor

Point scale factor of a transverse Mercator projection such as UTM from the easting, false easting, central scale factor and earth radius, in ppm and as a factor.

Inputs

Examples: Illustrative UTM point 140 km eastOn the central meridianState plane TM zone, 60 km west

Accepted: -10,000,000 to 10,000,000 m
Accepted: -10,000,000 to 10,000,000 m
Accepted: 0.99 to 1.01
Accepted: 6,300 to 6,400 km

Results

On a transverse Mercator projection the scale grows away from the central meridian: k ≈ k₀(1 + x²/2R² + x⁴/24R⁴), x the true distance east or west of it (grid offset ÷ k₀). UTM uses k₀ = 0.9996 so the scale is 1 about 180 km either side; state plane TM zones use smaller zones and k₀ nearer 1. The spherical approximation is within about 1 ppm inside a zone; rigorous ellipsoidal formulas are used for control work.

Distance from the central meridian0km
Point scale factor0.99960
Scale distortion (ppm)-400.00
Distance where k = 1 (secant lines)180.52km

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative UTM point 140 km east. The inputs, in the units selected above:

InputValue
Easting of the point640,000 m
False easting500,000 m
Scale factor on the central meridian0.99960 -
Earth radius (Gaussian mean)6,381.0 km

Applying the formula below gives:

ResultValue
Distance from the central meridian140.06 km
Point scale factor0.99984
Scale distortion (ppm)-159.21
Distance where k = 1 (secant lines)180.52 km

Open this example in the calculator and change any input.

Formula

\(k = k_0\left(1 + \frac{x^2}{2R^2} + \frac{x^4}{24R^4}\right), \quad x = \frac{E - E_0}{k_0}\)

Variables

Symbol Meaning SI unit
\(E\) Easting of the point m
\(E_0\) False easting m
\(k_0\) Scale factor on the central meridian -
\(R\) Earth radius (Gaussian mean) m
\(x\) Distance from the central meridian m
\(k\) Point scale factor -
\((k - 1)10^6\) Scale distortion (ppm) -
\(x_{k=1}\) Distance where k = 1 (secant lines) m

Method and standards

Projection scale.

Where it is used

  • Grid-ground conversions in UTM and TM zones.
  • Designing low-distortion projections.

Common mistakes

  • Forgetting the false easting.
  • Using the formula for Lambert zones.

Assumptions and limits

  • Spherical approximation; within one zone.

References

  • Transverse Mercator scale factor (spherical series)

Questions and answers

Why is k₀ less than 1?

To spread distortion: the scale is too small on the central meridian and too large near the zone edges, with exact scale on two lines between.

How large can UTM distortion get?

About −400 ppm on the central meridian to about +970 ppm at the zone edges near the equator.

What do the defaults represent?

An illustrative UTM point at easting 640,000 m, 140 km east of the central meridian.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Ghilani and Wolf, Elementary Surveying: An Introduction to Geomatics, 13th ed. (Pearson, 2012)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.