FireCADCalc

Three-Wire Levelling: Mean Readings and Sight Lengths

Mean backsight and foresight from upper, middle and lower cross-hair readings, the elevation difference, stadia sight lengths and their balance, with reading checks.

Inputs

Examples: Illustrative set-upFalling groundLong sights, 1 mm check error

Accepted: -10 to 10 m
Accepted: -10 to 10 m
Accepted: -10 to 10 m
Accepted: -10 to 10 m
Accepted: -10 to 10 m
Accepted: -10 to 10 m
Accepted: 50 to 200

Results

Each rod is read at all three cross-hairs and the mean used, reducing reading error. The upper-minus-lower interval × stadia constant (usually 100) gives the sight length, so backsights and foresights can be balanced to cancel collimation and curvature errors. The middle reading should equal the average of upper and lower within a millimetre or two; a larger difference indicates a misread.

Mean backsight0.70033m
Mean foresight2.4667m
Rise (+) or fall (−)-1.7663m
Backsight length28.300m
Foresight length28.900m
Sight length imbalance-0.60000m
Largest middle-wire check difference0.50000mm

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative set-up. The inputs, in the units selected above:

InputValue
Backsight upper wire1.9460 m
Backsight middle wire1.7760 m
Backsight lower wire1.6070 m
Foresight upper wire1.2140 m
Foresight middle wire1.0380 m
Foresight lower wire0.86300 m
Stadia constant100.00 -

Applying the formula below gives:

ResultValue
Mean backsight1.7763 m
Mean foresight1.0383 m
Rise (+) or fall (−)0.73800 m
Backsight length33.900 m
Foresight length35.100 m
Sight length imbalance-1.2000 m
Largest middle-wire check difference0.50000 mm

Open this example in the calculator and change any input.

Formula

\(\overline{BS} = \frac{B_U + B_M + B_L}{3}, \quad D_B = K(B_U - B_L), \quad \Delta h = \overline{BS} - \overline{FS}\)

Variables

Symbol Meaning SI unit
\(B_U\) Backsight upper wire m
\(B_M\) Backsight middle wire m
\(B_L\) Backsight lower wire m
\(F_U\) Foresight upper wire m
\(F_M\) Foresight middle wire m
\(F_L\) Foresight lower wire m
\(K\) Stadia constant -
\(\overline{BS}\) Mean backsight m
\(\overline{FS}\) Mean foresight m
\(\Delta h\) Rise (+) or fall (−) m
\(D_B\) Backsight length m
\(D_F\) Foresight length m
\(D_B - D_F\) Sight length imbalance m
\(\max|M - (U + L)/2|\) Largest middle-wire check difference m

Method and standards

Three-wire levelling.

Where it is used

  • Precise and control levelling.
  • Checking sight balance in the field.

Common mistakes

  • Swapping upper and lower readings.
  • Ignoring a failed middle-wire check.

Assumptions and limits

  • Stadia constant 100 and additive constant zero (internal-focusing level).

References

  • Three-wire levelling

Questions and answers

Why read three wires?

Averaging three readings reduces reading error, and the stadia interval gives the sight length for balancing.

Why balance sight lengths?

Equal backsight and foresight lengths cancel collimation error and curvature and refraction.

What do the defaults represent?

An illustrative set-up: backsight 1.946/1.776/1.607 m and foresight 1.214/1.038/0.863 m.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Ghilani and Wolf, Elementary Surveying: An Introduction to Geomatics, 13th ed. (Pearson, 2012)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.