FireCADCalc

Error Ellipse of a Survey Point

Semi-axes and orientation of the standard error ellipse of a point from its northing and easting standard errors and covariance, with the 95 % ellipse.

Inputs

Examples: Illustrative adjusted pointNegative correlationUncorrelated, east weaker

Accepted: 0 to 10,000 mm
Accepted: 0 to 10,000 mm
Accepted: -100 to 100

Results

The covariance matrix [σ_N², σ_NE; σ_NE, σ_E²] has eigenvalues S_u² and S_v² = (σ_N² + σ_E²)/2 ± √[((σ_N² − σ_E²)/2)² + σ_NE²], the squared semi-axes, and the major axis lies at azimuth t = ½·atan2(2σ_NE, σ_N² − σ_E²). The standard ellipse holds the true point with about 39 % probability; multiplying by √(−2 ln 0.05) = 2.448 gives the 95 % ellipse. Values come from a least-squares adjustment.

Semi-major axis (standard)10.000mm
Semi-minor axis (standard)6.0000mm
Azimuth of the semi-major axis90.000°
Semi-major axis, 95 %24.477mm
Semi-minor axis, 95 %14.686mm
Correlation coefficient0

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative adjusted point. The inputs, in the units selected above:

InputValue
Standard error of northing12.000 mm
Standard error of easting8.0000 mm
Covariance of N and E (m²)4.0000e-05 -

Applying the formula below gives:

ResultValue
Semi-major axis (standard)12.672 mm
Semi-minor axis (standard)6.8870 mm
Azimuth of the semi-major axis22.500 °
Semi-major axis, 95 %31.017 mm
Semi-minor axis, 95 %16.858 mm
Correlation coefficient0.41667

Open this example in the calculator and change any input.

Formula

\(S_{u,v}^2 = \frac{\sigma_N^2 + \sigma_E^2}{2} \pm \sqrt{\left(\frac{\sigma_N^2 - \sigma_E^2}{2}\right)^2 + \sigma_{NE}^2}, \quad t = \tfrac12\text{atan2}(2\sigma_{NE}, \sigma_N^2 - \sigma_E^2)\)

Variables

Symbol Meaning SI unit
\(\sigma_N\) Standard error of northing m
\(\sigma_E\) Standard error of easting m
\(\sigma_{NE}\) Covariance of N and E (m²) -
\(S_u\) Semi-major axis (standard) m
\(S_v\) Semi-minor axis (standard) m
\(t\) Azimuth of the semi-major axis rad
\(S_{u,95}\) Semi-major axis, 95 % m
\(S_{v,95}\) Semi-minor axis, 95 % m
\(\rho\) Correlation coefficient -

Method and standards

Error ellipse.

Where it is used

  • Reporting precision of control points.
  • Network design and analysis.

Common mistakes

  • Reading the standard ellipse as 95 %.
  • Covariance in the wrong units.

Assumptions and limits

  • Normally distributed errors; two-dimensional.

References

  • Error ellipses from least-squares covariance

Questions and answers

Why an ellipse rather than a circle?

Position errors usually differ by direction; the ellipse shows the strongest and weakest directions.

What probability does the standard ellipse represent?

About 39 %; scale by 2.448 for 95 %.

What do the defaults represent?

An illustrative adjusted point with σ_N 12 mm, σ_E 8 mm and covariance 4 × 10⁻⁵ m².

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Ghilani and Wolf, Elementary Surveying: An Introduction to Geomatics, 13th ed. (Pearson, 2012)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.