Worked example
Example: Illustrative 2.4 km line, 12 set-ups. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Starting benchmark level | 100.00 m |
| Sum of back sights | 18.745 m |
| Sum of fore sights | 15.130 m |
| Known closing benchmark level | 103.60 m |
| Length of the levelling route | 2.4000 km |
| Number of set-ups | 12.000 - |
| Permissible error constant (mm/√km) | 12.000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Observed closing level | 103.62 m |
| Misclosure (observed − known) | 15.000 mm |
| Permissible error | 18.590 mm |
| Ratio to permissible | 0.80687 |
| Correction per set-up | -1.2500 mm |
Open this example in the calculator and change any input.
Formula
\(RL_{obs} = RL_0 + \Sigma BS - \Sigma FS, \quad e_p = C\sqrt K, \quad c_s = -\frac en\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(RL_0\) | Starting benchmark level | m |
| \(\Sigma BS\) | Sum of back sights | m |
| \(\Sigma FS\) | Sum of fore sights | m |
| \(RL_1\) | Known closing benchmark level | m |
| \(K\) | Length of the levelling route | m |
| \(n\) | Number of set-ups | - |
| \(C\) | Permissible error constant (mm/√km) | - |
| \(RL_{obs}\) | Observed closing level | m |
| \(e\) | Misclosure (observed − known) | m |
| \(e_p\) | Permissible error | m |
| \(|e|/e_p\) | Ratio to permissible | - |
| \(c_s\) | Correction per set-up | m |
Method and standards
Misclosure.
Where it is used
- Checking and adjusting levelling runs.
- Site benchmark transfers.
Common mistakes
- Forgetting the sign of the correction.
- Using metres for K in C√K.
Assumptions and limits
- Random errors; equal set-up weights.
References
- Levelling closure and distribution of error
Questions and answers
Why does permissible error grow with √K?
Random errors accumulate with the number of set-ups, which is proportional to distance, so the total grows with its square root.
How is the error distributed?
Equally per set-up when sight lengths are similar, or in proportion to distance from the start.
What do the defaults represent?
An illustrative 2.4 km levelling line of 12 set-ups from a 100.000 m benchmark to a known 103.600 m benchmark.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Punmia, Jain and Jain, Surveying, Vol. 1, 16th ed. (Laxmi, 2005)