Tension Member: Gross, Net and Effective Area and Capacity

Gross area, net area on straight and staggered failure paths (s²/4g rule), effective net area with shear lag, and yield and rupture capacities of a plate or angle.

Thermal power plantProcess steam and utilitiesSugar mill and cogeneration

Inputs

Examples: Illustrative 200 x 12 plate, staggered holesWide stagger, straight path governsAngle leg 100 mm, one hole

Accepted: 20 to 2,000 mm
Accepted: 2 to 100 mm
Accepted: 5 to 60 mm
Accepted: 0 to 10
Accepted: 0 to 10
Accepted: 0 to 10
Accepted: 0 to 300 mm
Accepted: 10 to 300 mm
Accepted: 50 to 100 %
Accepted: 100 to 1,000 MPa
Accepted: 100 to 1,200 MPa
Accepted: 50 to 100 %
Accepted: 50 to 100 %

Results

A_n = (b − n·d_h + Σs²/4g)·t on each candidate path; the smallest governs. A_e = U·A_n allows for shear lag when only part of the section is connected. Capacity = min(φ_y·A_g·f_y, φ_u·A_e·f_u). Enter the hole size, U and factors your steel code prescribes; also check block shear at the connection.

Gross area1,520.0mm²
Net area, straight path1,376.0mm²
Net area, staggered path1,520.0mm²
Effective net area1,032.0mm²
Yield capacity on gross area485.64kN
Rupture capacity on effective net area379.26kN
Design tension capacity379.26kN

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 200 x 12 plate, staggered holes. The inputs, in the units selected above:

InputValue
Plate width (or developed angle width)200.00 mm
Thickness12.000 mm
Hole diameter22.000 mm
Holes on the straight path2.0000 -
Holes on the staggered path3.0000 -
Stagger spaces on that path2.0000 -
Stagger pitch (along the force)50.000 mm
Gauge (across the force)60.000 mm
Shear lag factor85.000 %
Yield stress250.00 MPa
Ultimate stress410.00 MPa
Yield resistance factor90.000 %
Rupture resistance factor75.000 %

Applying the formula below gives:

ResultValue
Gross area2,400.0 mm²
Net area, straight path1,872.0 mm²
Net area, staggered path1,858.0 mm²
Effective net area1,579.3 mm²
Yield capacity on gross area540.00 kN
Rupture capacity on effective net area485.63 kN
Design tension capacity485.63 kN

Open this example in the calculator and change any input.

Formula

\(A_n = \left(b - nd_h + \sum\frac{s^2}{4g}\right)t, \quad A_e = UA_n, \quad T_d = \min(\phi_yA_gf_y,\ \phi_uA_ef_u)\)

Variables

Symbol Meaning SI unit
\(b\) Plate width (or developed angle width) m
\(t\) Thickness m
\(d_h\) Hole diameter m
\(n_1\) Holes on the straight path -
\(n_2\) Holes on the staggered path -
\(n_s\) Stagger spaces on that path -
\(s\) Stagger pitch (along the force) m
\(g\) Gauge (across the force) m
\(U\) Shear lag factor -
\(f_y\) Yield stress Pa
\(f_u\) Ultimate stress Pa
\(\phi_y\) Yield resistance factor -
\(\phi_u\) Rupture resistance factor -
\(A_g\) Gross area m²
\(A_{n,1}\) Net area, straight path m²
\(A_{n,2}\) Net area, staggered path m²
\(A_e\) Effective net area m²
\(T_y\) Yield capacity on gross area N
\(T_u\) Rupture capacity on effective net area N
\(T_d\) Design tension capacity N

Method and standards

Tension member.

Where it is used

  • Truss members, bracing and hangers.
  • Splice and gusset plate checks.

Common mistakes

  • Checking only the straight path.
  • Forgetting shear lag for angles connected by one leg.

Assumptions and limits

  • Static tension; holes of one size; no block shear check.

References

  • Net-section rule with Cochrane s²/4g stagger term

Questions and answers

Why does a staggered path add s²/4g?

A zig-zag path is longer and carries some load in shear, so each stagger adds back part of a hole's lost width.

What is shear lag?

When only some legs are bolted, stress concentrates near the connection and the full net area does not develop; U reduces it.

What do the defaults represent?

An illustrative 200 × 12 mm plate with 22 mm holes: 2 holes straight across, or 3 holes over 2 staggers of 50 mm pitch and 60 mm gauge, U 0.85, f_y 250 and f_u 410 MPa.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Salmon, Johnson and Malhas, Steel Structures: Design and Behavior, 5th ed. (Pearson, 2009)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.