Worked example
Example: Illustrative 200 x 12 plate, staggered holes. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Plate width (or developed angle width) | 200.00 mm |
| Thickness | 12.000 mm |
| Hole diameter | 22.000 mm |
| Holes on the straight path | 2.0000 - |
| Holes on the staggered path | 3.0000 - |
| Stagger spaces on that path | 2.0000 - |
| Stagger pitch (along the force) | 50.000 mm |
| Gauge (across the force) | 60.000 mm |
| Shear lag factor | 85.000 % |
| Yield stress | 250.00 MPa |
| Ultimate stress | 410.00 MPa |
| Yield resistance factor | 90.000 % |
| Rupture resistance factor | 75.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Gross area | 2,400.0 mm² |
| Net area, straight path | 1,872.0 mm² |
| Net area, staggered path | 1,858.0 mm² |
| Effective net area | 1,579.3 mm² |
| Yield capacity on gross area | 540.00 kN |
| Rupture capacity on effective net area | 485.63 kN |
| Design tension capacity | 485.63 kN |
Open this example in the calculator and change any input.
Formula
\(A_n = \left(b - nd_h + \sum\frac{s^2}{4g}\right)t, \quad A_e = UA_n, \quad T_d = \min(\phi_yA_gf_y,\ \phi_uA_ef_u)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(b\) | Plate width (or developed angle width) | m |
| \(t\) | Thickness | m |
| \(d_h\) | Hole diameter | m |
| \(n_1\) | Holes on the straight path | - |
| \(n_2\) | Holes on the staggered path | - |
| \(n_s\) | Stagger spaces on that path | - |
| \(s\) | Stagger pitch (along the force) | m |
| \(g\) | Gauge (across the force) | m |
| \(U\) | Shear lag factor | - |
| \(f_y\) | Yield stress | Pa |
| \(f_u\) | Ultimate stress | Pa |
| \(\phi_y\) | Yield resistance factor | - |
| \(\phi_u\) | Rupture resistance factor | - |
| \(A_g\) | Gross area | m² |
| \(A_{n,1}\) | Net area, straight path | m² |
| \(A_{n,2}\) | Net area, staggered path | m² |
| \(A_e\) | Effective net area | m² |
| \(T_y\) | Yield capacity on gross area | N |
| \(T_u\) | Rupture capacity on effective net area | N |
| \(T_d\) | Design tension capacity | N |
Method and standards
Tension member.
Where it is used
- Truss members, bracing and hangers.
- Splice and gusset plate checks.
Common mistakes
- Checking only the straight path.
- Forgetting shear lag for angles connected by one leg.
Assumptions and limits
- Static tension; holes of one size; no block shear check.
References
- Net-section rule with Cochrane s²/4g stagger term
Questions and answers
Why does a staggered path add s²/4g?
A zig-zag path is longer and carries some load in shear, so each stagger adds back part of a hole's lost width.
What is shear lag?
When only some legs are bolted, stress concentrates near the connection and the full net area does not develop; U reduces it.
What do the defaults represent?
An illustrative 200 × 12 mm plate with 22 mm holes: 2 holes straight across, or 3 holes over 2 staggers of 50 mm pitch and 60 mm gauge, U 0.85, f_y 250 and f_u 410 MPa.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Salmon, Johnson and Malhas, Steel Structures: Design and Behavior, 5th ed. (Pearson, 2009)