Worked example
Example: Illustrative 6 m, 15 kN/m plus 20 kN. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Span | 6.0000 m |
| Uniform load | 15.000 kN/m |
| Central point load | 20.000 kN |
| Allowable bending stress | 165.00 MPa |
| Elastic modulus | 200.00 GPa |
| Deflection limit L/n | 360.00 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Maximum moment | 97.500 kN·m |
| Maximum shear | 55.000 kN |
| Section modulus needed | 590.91 cm³ |
| Second moment of area for deflection | 10,294 cm⁴ |
| Allowable deflection | 16.667 mm |
Open this example in the calculator and change any input.
Formula
\(M = \frac{wL^2}{8} + \frac{PL}{4}, \quad Z_{req} = \frac{M}{\sigma_{all}}, \quad I_{req} = \frac{1}{E\delta_{all}}\left(\frac{5wL^4}{384} + \frac{PL^3}{48}\right)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(L\) | Span | m |
| \(w\) | Uniform load | N/m |
| \(P\) | Central point load | N |
| \(\sigma_{all}\) | Allowable bending stress | Pa |
| \(E\) | Elastic modulus | Pa |
| \(n\) | Deflection limit L/n | - |
| \(M_{max}\) | Maximum moment | N·m |
| \(V_{max}\) | Maximum shear | N |
| \(Z_{req}\) | Section modulus needed | m³ |
| \(I_{req}\) | Second moment of area for deflection | m⁴ |
| \(\delta_{all}\) | Allowable deflection | m |
Method and standards
Beam selection.
Where it is used
- Floor and roof beams, crane runway checks.
- Quick section choice before detailed design.
Common mistakes
- Checking strength but not deflection.
- Ignoring lateral-torsional buckling of unrestrained beams.
Assumptions and limits
- Simply supported prismatic beam; elastic.
References
- Elastic beam selection by strength and stiffness
- Gere and Goodno
- Mechanics of Materials (Cengage)
Questions and answers
Which governs, strength or deflection?
Long spans and light loads are usually governed by deflection, short heavily loaded beams by bending or shear.
Should I use factored loads for deflection?
No: deflection is a serviceability check with unfactored service loads.
What do the defaults represent?
An illustrative 6 m simply supported beam with 15 kN/m uniform load plus 20 kN at midspan, allowable stress 165 MPa, limit L/360.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.