FireCADCalc

Steel Beam Section Modulus and Inertia Required

Maximum moment and shear of a simply supported beam with uniform and central point loads, and the section modulus and second moment of area needed.

Inputs

Examples: Illustrative 6 m, 15 kN/m plus 20 kNLong 10 m roof beam 8 kN/mShort 3 m beam, 100 kN point

Accepted: 0.5 to 50 m
Accepted: 0 to 1,000 kN/m
Accepted: 0 to 10,000 kN
Accepted: 50 to 500 MPa
Accepted: 50 to 250 GPa
Accepted: 100 to 1,000

Results

M = wL²/8 + PL/4; Z = M/σ; I from δ = 5wL⁴/384EI + PL³/48EI. Pick a section with both Z and I above these, then check lateral-torsional buckling, web shear and bearing; use service loads for deflection.

Maximum moment97.500kN·m
Maximum shear55.000kN
Section modulus needed590.91cm³
Second moment of area for deflection10,294cm⁴
Allowable deflection16.667mm

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 6 m, 15 kN/m plus 20 kN. The inputs, in the units selected above:

InputValue
Span6.0000 m
Uniform load15.000 kN/m
Central point load20.000 kN
Allowable bending stress165.00 MPa
Elastic modulus200.00 GPa
Deflection limit L/n360.00 -

Applying the formula below gives:

ResultValue
Maximum moment97.500 kN·m
Maximum shear55.000 kN
Section modulus needed590.91 cm³
Second moment of area for deflection10,294 cm⁴
Allowable deflection16.667 mm

Open this example in the calculator and change any input.

Formula

\(M = \frac{wL^2}{8} + \frac{PL}{4}, \quad Z_{req} = \frac{M}{\sigma_{all}}, \quad I_{req} = \frac{1}{E\delta_{all}}\left(\frac{5wL^4}{384} + \frac{PL^3}{48}\right)\)

Variables

Symbol Meaning SI unit
\(L\) Span m
\(w\) Uniform load N/m
\(P\) Central point load N
\(\sigma_{all}\) Allowable bending stress Pa
\(E\) Elastic modulus Pa
\(n\) Deflection limit L/n -
\(M_{max}\) Maximum moment N·m
\(V_{max}\) Maximum shear N
\(Z_{req}\) Section modulus needed m³
\(I_{req}\) Second moment of area for deflection m⁴
\(\delta_{all}\) Allowable deflection m

Method and standards

Beam selection.

Where it is used

  • Floor and roof beams, crane runway checks.
  • Quick section choice before detailed design.

Common mistakes

  • Checking strength but not deflection.
  • Ignoring lateral-torsional buckling of unrestrained beams.

Assumptions and limits

  • Simply supported prismatic beam; elastic.

References

  • Elastic beam selection by strength and stiffness
  • Gere and Goodno
  • Mechanics of Materials (Cengage)

Questions and answers

Which governs, strength or deflection?

Long spans and light loads are usually governed by deflection, short heavily loaded beams by bending or shear.

Should I use factored loads for deflection?

No: deflection is a serviceability check with unfactored service loads.

What do the defaults represent?

An illustrative 6 m simply supported beam with 15 kN/m uniform load plus 20 kN at midspan, allowable stress 165 MPa, limit L/360.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.