FireCADCalc

Shear Flow and Fastener Spacing in a Built-Up Beam

Shear flow at a joint of a built-up beam from shear force, first moment of area and second moment of area, and the bolt, nail or weld spacing needed.

Inputs

Examples: Illustrative plate girder jointTimber box beam nailsWelded flange, one fastener equivalent

Accepted: 0.001 to 1,000,000 kN
Accepted: 0.01 to 10,000,000 cm³
Accepted: 0.01 to 1E+10 cm⁴
Accepted: 0.001 to 100,000 kN
Accepted: 1 to 20
Accepted: 1 to 10,000 mm

Results

Bending stresses differ on either side of a short length of beam, and the difference must be passed across any joint between the parts as a longitudinal shear flow q = VQ/I, where Q is the first moment about the neutral axis of the part outside the joint. Fasteners at spacing s each carry q·s/n_f, so s ≤ n_fF_c/q; welds must resist q per metre. Spacing can widen where the shear force is smaller, but stays within detailing limits.

Shear flow400.00kN/m
Maximum fastener row spacing500.00mm
Shear stress at the joint26.667MPa

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative plate girder joint. The inputs, in the units selected above:

InputValue
Shear force120.00 kN
First moment of the connected part about the neutral axis900.00 cm³
Second moment of area of the whole section45,000 cm⁴
Capacity of one fastener60.000 kN
Fasteners per row (across the joint)2.0000 -
Width at the joint (for stress)12.000 mm

Applying the formula below gives:

ResultValue
Shear flow240.00 kN/m
Maximum fastener row spacing500.00 mm
Shear stress at the joint20.000 MPa

Open this example in the calculator and change any input.

Formula

\(q = \frac{VQ}{I}, \quad s = \frac{n_fF_c}{q}, \quad \tau = \frac qb\)

Variables

Symbol Meaning SI unit
\(V\) Shear force N
\(Q\) First moment of the connected part about the neutral axis m³
\(I\) Second moment of area of the whole section m⁴
\(F_c\) Capacity of one fastener N
\(n_f\) Fasteners per row (across the joint) -
\(b\) Width at the joint (for stress) m
\(q\) Shear flow N/m
\(s\) Maximum fastener row spacing m
\(\tau\) Shear stress at the joint Pa

Method and standards

Shear flow.

Where it is used

  • Plate girders, box beams and timber built-up beams.
  • Weld size for flange-to-web joints.

Common mistakes

  • Using Q of the whole half-section instead of the connected part.
  • Forgetting the number of fasteners in a row.

Assumptions and limits

  • Elastic bending; prismatic section; shear evenly shared by fasteners in a row.

References

  • Shear flow in built-up members

Questions and answers

What is Q here?

The first moment of area about the neutral axis of the part joined by the fasteners (for example one flange plate).

Why can spacing increase towards midspan?

Shear force, and with it shear flow, usually falls towards midspan.

What do the defaults represent?

An illustrative plate girder joint: 120 kN shear, Q = 900 cm³, I = 45,000 cm⁴, two bolts per row of 60 kN each.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Timoshenko and Gere, Mechanics of Materials, 4th ed. (PWS, 1997)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.