Roof Snow Load from Ground Snow and Roof Factors

Roof snow load from ground snow load and shape, exposure and thermal factors, with the load on the sloping roof surface and the total on a roof area.

Inputs

Examples: Illustrative 1.5 kPa, 20 deg roof, 200 m2Mountain 4 kPa, sheltered, heatedSteep 45 deg roof

Accepted: 0 to 20 kPa
Accepted: 0 to 3
Accepted: 0.5 to 1.5
Accepted: 0.5 to 1.5
Accepted: 0 to 80.214 °
Accepted: 1 to 1,000,000 m²

Results

s = μ·C_e·C_t·s_g on the horizontal projection. Shape coefficients fall on steep roofs and rise for drifts at steps, parapets and valleys; take ground snow and the factors from your national code.

Snow load on plan area0.80000kPa
Snow load per m² of roof surface0.56569kPa
Total snow load on the roof96.000kN

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 1.5 kPa, 20 deg roof, 200 m2. The inputs, in the units selected above:

InputValue
Ground snow load1.5000 kPa
Roof shape coefficient0.80000 -
Exposure factor1.0000 -
Thermal factor1.0000 -
Roof slope20.000 °
Roof plan area200.00 m²

Applying the formula below gives:

ResultValue
Snow load on plan area1.2000 kPa
Snow load per m² of roof surface1.1276 kPa
Total snow load on the roof240.00 kN

Open this example in the calculator and change any input.

Formula

\(s = \mu C_eC_ts_g, \quad s_\alpha = s\cos\alpha, \quad F = sA_p\)

Variables

Symbol Meaning SI unit
\(s_g\) Ground snow load Pa
\(\mu\) Roof shape coefficient -
\(C_e\) Exposure factor -
\(C_t\) Thermal factor -
\(\alpha\) Roof slope rad
\(A_p\) Roof plan area m²
\(s\) Snow load on plan area Pa
\(s_\alpha\) Snow load per m² of roof surface Pa
\(F\) Total snow load on the roof N

Method and standards

Snow load.

Where it is used

  • Roof and purlin design.
  • Checking older roofs for heavy snow.

Common mistakes

  • Applying the plan load to the sloping area.
  • Ignoring drifts at steps and parapets.

Assumptions and limits

  • Uniform snow; no drift.

References

  • Roof snow load from ground snow with shape
  • exposure and thermal factors
  • Practice common to national snow load codes

Questions and answers

Why is roof snow less than ground snow?

Wind blows snow off exposed roofs and heat through the roof melts some; steep roofs shed snow.

Where are snow loads highest?

In drifts behind parapets, at roof steps and in valleys, often two to three times the uniform value.

What do the defaults represent?

An illustrative 1.5 kPa ground snow on a 20° roof with shape coefficient 0.8, normal exposure and an unheated building factor of 1.0, over 200 m² of plan.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.