FireCADCalc

Roof Purlin under Biaxial Bending with Sag Rods

Bending moments about both axes of a purlin on a sloping roof, with sag rods reducing the weak-axis span, and the combined bending stress ratio.

Thermal power plantProcess steam and utilitiesSugar mill and cogeneration

Inputs

Examples: Illustrative 1.5 kN/m, 6 m, 15 deg, one sag rodNo sag rods, 10 degTwo sag rods, steep 25 deg roof

Accepted: 0.01 to 100 kN/m
Accepted: 0 to 68.755 °
Accepted: 1 to 15 m
Accepted: 1 to 10,000 cm³
Accepted: 0.1 to 10,000 cm³
Accepted: 50 to 600 MPa

Results

Load splits into w·cosθ normal to the roof and w·sinθ along it. M_x = w·cosθ·L²/8 (simply supported). Along the slope the sag rods act as supports: one rod gives a two-span continuous beam, M_y = w·sinθ(L/2)²/8 at the rod; two rods give about 0.1·w·sinθ(L/3)². Ratio = f_bx/f_b + f_by/f_b ≤ 1 (use the user's code interaction and lateral-torsional checks, and wind suction as a separate case).

Strong-axis moment14.019kN·m
Weak-axis moment0.58110kN·m
Strong-axis stress93.463MPa
Weak-axis stress23.244MPa
Combined stress ratio0.70732

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 1.5 kN/m, 6 m, 15 deg, one sag rod. The inputs, in the units selected above:

InputValue
Gravity load on purlin per metre1.5000 kN/m
Roof slope15.000 °
Purlin span (between rafters)6.0000 m
Sag rodsOne at mid-span
Section modulus, strong axis89.000 cm³
Section modulus, weak axis14.700 cm³
Allowable bending stress165.00 MPa

Applying the formula below gives:

ResultValue
Strong-axis moment6.5200 kN·m
Weak-axis moment0.43676 kN·m
Strong-axis stress73.258 MPa
Weak-axis stress29.711 MPa
Combined stress ratio0.62406

Open this example in the calculator and change any input.

Formula

\(M_x = \frac{w\cos\theta L^2}{8}, \quad M_y = \frac{w\sin\theta (L/2)^2}{8}, \quad \eta = \frac{M_x/Z_x + M_y/Z_y}{f_b}\)

Variables

Symbol Meaning SI unit
\(w\) Gravity load on purlin per metre N/m
\(\theta\) Roof slope rad
\(L\) Purlin span (between rafters) m
\(n_{sag}\) Sag rods -
\(Z_x\) Section modulus, strong axis m³
\(Z_y\) Section modulus, weak axis m³
\(f_b\) Allowable bending stress Pa
\(M_x\) Strong-axis moment N·m
\(M_y\) Weak-axis moment N·m
\(f_{bx}\) Strong-axis stress Pa
\(f_{by}\) Weak-axis stress Pa
\(\eta\) Combined stress ratio -

Method and standards

Purlin bending.

Where it is used

  • Industrial shed and boiler house roofs.
  • Side rails (girts) with the same method.

Common mistakes

  • Ignoring the weak-axis component.
  • Using sag rods without anchoring them at the ridge.

Assumptions and limits

  • Load through the shear centre; simple strong-axis span.

References

  • Biaxial bending with continuous weak-axis spans

Questions and answers

Why use sag rods?

Purlins are weak about the axis along the roof; sag rods cut that span, reducing weak-axis bending and twisting.

Which load cases matter?

Dead plus live or snow downward, and dead minus wind suction upward, which puts the unbraced bottom flange in compression.

What do the defaults represent?

An illustrative 1.5 kN/m on a channel purlin (Z_x 89 cm³, Z_y 14.7 cm³) spanning 6 m on a 15° roof with one mid-span sag rod and 165 MPa allowable.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Subramanian, Design of Steel Structures (Oxford University Press, 2008)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.