FireCADCalc

Lateral Load on a Single-Storey Multi-Bay Frame (Portal Method)

Column shears and moments, beam moments and shears and exterior column axial forces of a one-storey multi-bay frame under lateral load (portal method).

Inputs

Examples: Illustrative three-bay frameSingle portalFive bays

Accepted: 0.001 to 100,000 kN
Accepted: 1 to 20
Accepted: 0.5 to 50 m
Accepted: 0.5 to 100 m

Results

The portal method assumes points of contraflexure at mid-height of every column and midspan of every beam, and that each bay acts as a portal, so interior columns take twice the shear of exterior ones: V_ext = H/(2n_b), V_int = H/n_b. Column end moments are V·h/2. At an exterior joint the beam moment equals the column moment, the beam shear is 2M_b/L, and only the exterior columns carry axial force (equal and opposite) because beam shears cancel at interior joints. It suits low, regular frames with fixed bases; use the cantilever method for tall, slender frames.

Shear in each exterior column15.000kN
Shear in each interior column30.000kN
Exterior column end moment33.750kN·m
Interior column end moment67.500kN·m
Beam end moment33.750kN·m
Beam shear9.0000kN
Exterior column axial force9.0000kN

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative three-bay frame. The inputs, in the units selected above:

InputValue
Lateral load at beam level60.000 kN
Number of bays3.0000 -
Storey height4.0000 m
Bay width6.0000 m

Applying the formula below gives:

ResultValue
Shear in each exterior column10.000 kN
Shear in each interior column20.000 kN
Exterior column end moment20.000 kN·m
Interior column end moment40.000 kN·m
Beam end moment20.000 kN·m
Beam shear6.6667 kN
Exterior column axial force6.6667 kN

Open this example in the calculator and change any input.

Formula

\(V_{ext} = \frac{H}{2n_b}, \quad V_{int} = \frac{H}{n_b}, \quad M = V\frac h2, \quad V_b = \frac{2M_b}{L}\)

Variables

Symbol Meaning SI unit
\(H\) Lateral load at beam level N
\(n_b\) Number of bays -
\(h\) Storey height m
\(L\) Bay width m
\(V_{ext}\) Shear in each exterior column N
\(V_{int}\) Shear in each interior column N
\(M_{ext}\) Exterior column end moment N·m
\(M_{int}\) Interior column end moment N·m
\(M_b\) Beam end moment N·m
\(V_b\) Beam shear N
\(N_{ext}\) Exterior column axial force N

Method and standards

Portal method.

Where it is used

  • Preliminary design of frames for wind or seismic load.
  • Checking computer analysis.

Common mistakes

  • Using it for pinned-base frames.
  • Applying it to tall frames.

Assumptions and limits

  • Fixed bases; equal bays; contraflexure at mid-height and midspan.

References

  • Portal method of approximate analysis

Questions and answers

Why do interior columns take double shear?

Each interior column belongs to two portals, each contributing the same shear as an exterior column.

When is the method inaccurate?

For tall frames dominated by overall bending, unequal bays or pinned bases.

What do the defaults represent?

An illustrative three-bay frame, 4 m high with 6 m bays, under a 60 kN lateral load.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Hibbeler, Structural Analysis, 10th ed. (Pearson, 2018)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.