FireCADCalc

Plastic Collapse Load of a Beam

Plastic moment and collapse load of simply supported, propped cantilever and fixed-ended beams under a central point load or uniform load, with the load factor.

Inputs

Examples: Illustrative propped cantilever, uniform loadFixed beam, central point loadSimply supported, uniform load

Accepted: 0.1 to 1,000,000 cm³
Accepted: 10 to 2,000 MPa
Accepted: 0.1 to 100 m
Accepted: 0 to 1,000,000 kN

Results

The plastic moment M_p = Z_pf_y is the moment a fully yielded section carries. Collapse needs enough plastic hinges to form a mechanism; equating external work to M_p times the hinge rotations gives W_c = 4M_p/L (simply supported, central load), 6M_p/L (propped), 8M_p/L (fixed), and for a total uniform load W = wL: 8M_p/L, 11.66M_p/L (propped, hinge at 0.414L from the propped end) and 16M_p/L (fixed). Plastic design needs compact sections and lateral restraint so that hinges can rotate without local or lateral buckling.

Plastic moment887.50kN·m
Collapse load (total)710.00kN
Load factor against collapse1.7750
Sagging hinge position from the propped end5.0000m

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative propped cantilever, uniform load. The inputs, in the units selected above:

InputValue
Plastic section modulus1,000.0 cm³
Yield stress275.00 MPa
Span8.0000 m
Support and load casePropped cantilever, uniform load
Working (service) total load150.00 kN

Applying the formula below gives:

ResultValue
Plastic moment275.00 kN·m
Collapse load (total)400.70 kN
Load factor against collapse2.6714
Sagging hinge position from the propped end3.3137 m

Open this example in the calculator and change any input.

Formula

\(M_p = Z_pf_y, \quad W_c = \frac{\alpha M_p}{L}, \quad \alpha = 4, 6, 8 \text{ (point)};\; 8, 6 + 4\sqrt2, 16 \text{ (uniform)}\)

Variables

Symbol Meaning SI unit
\(Z_p\) Plastic section modulus m³
\(f_y\) Yield stress Pa
\(L\) Span m
\(\text{case}\) Support and load case -
\(W_s\) Working (service) total load N
\(M_p\) Plastic moment N·m
\(W_c\) Collapse load (total) N
\(\lambda\) Load factor against collapse -
\(x_h\) Sagging hinge position from the propped end m

Method and standards

Plastic collapse.

Where it is used

  • Plastic design of continuous steel beams.
  • Checking reserve strength.

Common mistakes

  • Using the elastic modulus for M_p.
  • Ignoring lateral-torsional buckling.

Assumptions and limits

  • Compact, laterally restrained section; rigid-plastic behaviour; no axial or shear interaction.

References

  • Plastic hinge mechanism method

Questions and answers

Why does a fixed beam carry twice the simply supported load?

It needs three hinges instead of one, and the end hinges share the work.

Where is the sagging hinge in a propped cantilever under uniform load?

At 0.414L from the propped end, giving W_c = 11.66M_p/L.

What do the defaults represent?

An illustrative 8 m propped cantilever with Z_p = 1,000 cm³, f_y = 275 MPa and 150 kN total working load.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Neal, The Plastic Methods of Structural Analysis, 3rd ed. (Chapman and Hall, 1977)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.