FireCADCalc

Wind Bracing Diagonal: Force, Slenderness and Buckling Load

Axial force and stress in the diagonal of a braced bay from a horizontal load, for tension-only or paired bracing, with slenderness and Euler load.

Thermal power plantProcess steam and utilitiesSugar mill and cogeneration

Inputs

Examples: Illustrative 120 kN on 6 x 5 m bay, tension onlyPaired diagonals, 8 x 4 mRoof bracing rod 20 mm

Accepted: 0.1 to 100,000 kN
Accepted: 0.5 to 30 m
Accepted: 0.5 to 30 m
Accepted: 10 to 50,000 mm²
Accepted: 1 to 300 mm
Accepted: 10 to 300 GPa
Accepted: 0.5 to 2

Results

F = H/cosα = H·L_d/b for one acting diagonal; with both diagonals sharing, each carries half, one in tension and one in compression. Compare compression with the user's column curve rather than Euler alone; tension-only rods and flats are usually limited to slenderness of a few hundred to stop sag and rattle.

Diagonal length7.0711m
Diagonal force21.213kN
Axial stress67.558MPa
Slenderness ratio1,414.2
Euler buckling load0.30991kN

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 120 kN on 6 x 5 m bay, tension only. The inputs, in the units selected above:

InputValue
Horizontal force on the bay120.00 kN
Bay width6.0000 m
Bay height5.0000 m
Bracing actionTension-only (one diagonal acts)
Diagonal cross-section area1,500.0 mm²
Minimum radius of gyration30.000 mm
Elastic modulus200.00 GPa
Effective length factor0.85000 -

Applying the formula below gives:

ResultValue
Diagonal length7.8102 m
Diagonal force156.20 kN
Axial stress104.14 MPa
Slenderness ratio221.29
Euler buckling load60.464 kN

Open this example in the calculator and change any input.

Formula

\(L_d = \sqrt{b^2 + h^2}, \quad F = \frac{HL_d}{b}, \quad P_E = \frac{\pi^2EA}{(KL_d/r)^2}\)

Variables

Symbol Meaning SI unit
\(H\) Horizontal force on the bay N
\(b\) Bay width m
\(h\) Bay height m
\(\text{mode}\) Bracing action -
\(A\) Diagonal cross-section area m²
\(r\) Minimum radius of gyration m
\(E\) Elastic modulus Pa
\(K\) Effective length factor -
\(L_d\) Diagonal length m
\(F\) Diagonal force N
\(\sigma\) Axial stress Pa
\(KL/r\) Slenderness ratio -
\(P_E\) Euler buckling load N

Method and standards

Bracing force.

Where it is used

  • Wall and roof wind bracing.
  • Crane and pipe rack longitudinal bracing.

Common mistakes

  • Counting a slender compression diagonal.
  • Forgetting the vertical force the bracing puts into columns.

Assumptions and limits

  • Pin-jointed bay; single horizontal load; elastic buckling.

References

  • Statics of a braced bay; Euler buckling

Questions and answers

Why design tension-only bracing?

Slender rods and flats buckle at tiny loads, so only the diagonal in tension is counted; the other goes slack.

What effective length for crossed diagonals?

Connected at the crossing, a compression diagonal often buckles over about half its length out of plane; the user's code sets K.

What do the defaults represent?

An illustrative 120 kN wind force on a 6 m wide by 5 m high bay with a 1,500 mm² angle (r 30 mm) in tension-only bracing.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Timoshenko and Gere, Theory of Elastic Stability, 2nd ed. (McGraw-Hill, 1961), Subramanian, Design of Steel Structures (Oxford University Press, 2008)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.