Worked example
Example: Illustrative 300 x 450 beam, 8 mm at 150. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Beam width | 300.00 mm |
| Beam overall depth | 450.00 mm |
| Clear cover to stirrup | 25.000 mm |
| Stirrup bar diameter | 8.0000 mm |
| Hook length (bar diameters, each) | 10.000 - |
| Deduction per 90° bend (bar diameters) | 2.0000 - |
| Deduction per 135° bend (bar diameters) | 3.0000 - |
| Length to be stirruped | 6.0000 m |
| Stirrup spacing | 150.00 mm |
Applying the formula below gives:
| Result | Value |
|---|---|
| Inside width (centreline) | 242.00 mm |
| Inside height (centreline) | 392.00 mm |
| Cutting length | 1,332.0 mm |
| Number of stirrups | 41.000 |
| Steel weight | 21.549 kg |
Open this example in the calculator and change any input.
Formula
\(L_c = 2(a + h) + 2k_h\phi - 3k_{90}\phi - 2k_{135}\phi, \quad n = \left\lfloor\frac{L}{s}\right\rfloor + 1\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(b\) | Beam width | m |
| \(D\) | Beam overall depth | m |
| \(c\) | Clear cover to stirrup | m |
| \(\phi\) | Stirrup bar diameter | m |
| \(k_h\) | Hook length (bar diameters, each) | - |
| \(k_{90}\) | Deduction per 90° bend (bar diameters) | - |
| \(k_{135}\) | Deduction per 135° bend (bar diameters) | - |
| \(L\) | Length to be stirruped | m |
| \(s\) | Stirrup spacing | m |
| \(a\) | Inside width (centreline) | m |
| \(h\) | Inside height (centreline) | m |
| \(L_c\) | Cutting length | m |
| \(n\) | Number of stirrups | - |
| \(m\) | Steel weight | kg |
Method and standards
Stirrup schedule.
Where it is used
- Bar bending schedules for beams and columns.
- Steel ordering and checking.
Common mistakes
- Using outer dimensions without cover.
- Forgetting the extra stirrup at the end.
Assumptions and limits
- Closed rectangular stirrups with two 135° hooks.
References
- Bar bending schedule practice
Questions and answers
Why deduct for bends?
Bars are measured along the outside when ordered but bend around a mandrel, so each bend uses less length than the sharp-corner dimension.
Why 135° hooks?
They anchor into the core and keep stirrups closed if cover spalls, which matters in seismic zones.
What do the defaults represent?
An illustrative 300 × 450 mm beam, 25 mm cover, 8 mm stirrups with 10φ hooks at 150 mm spacing over 6 m.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Dutta, Estimating and Costing in Civil Engineering, 28th ed. (UBS, 2020)