FireCADCalc

Field Vane Undrained Shear Strength

Undrained shear strength of clay from the peak torque on a vane of given height and diameter, with uniform shear on sides and ends, and a plasticity correction.

Thermal power plantProcess steam and utilitiesSugar mill and cogeneration

Inputs

Examples: Illustrative 65 x 130 mm vane, 60 N mSoft clay 75 x 150 mm, 25 N mSmall lab vane 12.7 x 12.7 mm

Accepted: 0.1 to 10,000 N·m
Accepted: 10 to 200 mm
Accepted: 10 to 400 mm
Accepted: 0.5 to 1.2

Results

Torque resisted by the cylinder sides (πD²H/2·s_u) and both ends (πD³/6·s_u): T = s_uπD²(H/2 + D/6). Vane strengths in plastic clays are corrected by Bjerrum's factor μ (falling with plasticity index); enter μ from the chart the user's practice follows.

Vane constant4.2901cm³
Vane shear strength81.583kPa
Corrected undrained strength81.583kPa

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 65 x 130 mm vane, 60 N m. The inputs, in the units selected above:

InputValue
Maximum torque60.000 N·m
Vane diameter65.000 mm
Vane height130.00 mm
Correction factor (from plasticity, user's chart)0.85000 -

Applying the formula below gives:

ResultValue
Vane constant1,006.6 cm³
Vane shear strength59.609 kPa
Corrected undrained strength50.668 kPa

Open this example in the calculator and change any input.

Formula

\(T = s_u\pi D^2\left(\frac H2 + \frac D6\right), \quad s_{u,corr} = \mu s_u\)

Variables

Symbol Meaning SI unit
\(T\) Maximum torque N·m
\(D\) Vane diameter m
\(H\) Vane height m
\(\mu\) Correction factor (from plasticity, user's chart) -
\(K_v\) Vane constant m³
\(s_{u,v}\) Vane shear strength Pa
\(s_u\) Corrected undrained strength Pa

Method and standards

Vane strength.

Where it is used

  • Soft clay site investigation.
  • Embankment and excavation stability on soft ground.

Common mistakes

  • Using residual torque for peak strength.
  • Forgetting the end contribution.

Assumptions and limits

  • Uniform shear stress on sides and ends; undrained.

References

  • Field vane test interpretation

Questions and answers

Why correct the vane strength?

Fast vane shearing and strength anisotropy overestimate field strength in plastic clays; embankment failures led to the correction.

Which vane size?

A height-to-diameter ratio of 2 is standard; smaller vanes for stiffer clays.

What do the defaults represent?

An illustrative 65 × 130 mm vane at 60 N·m peak torque with a correction factor of 0.85.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Das and Sobhan, Principles of Geotechnical Engineering, 8th ed. (Cengage, 2014), Holtz, Kovacs and Sheahan, An Introduction to Geotechnical Engineering, 2nd ed. (Pearson, 2011)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.