Worked example
Example: Illustrative 30 min reading. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Effective depth | 140.00 mm |
| Time since start | 30.000 min |
| Water viscosity at test temperature | 1.0000 mPa·s |
| Specific gravity of solids | 2.7000 - |
| Corrected hydrometer reading (g/L) | 18.000 - |
| Dry soil mass in 1 L suspension (g) | 50.000 - |
Applying the formula below gives:
| Result | Value |
|---|---|
| Settling velocity | 0.077778 mm/s |
| Equivalent particle diameter | 9.1639 µm |
| Percent finer than D | 57.176 % |
Open this example in the calculator and change any input.
Formula
\(D = \sqrt{\frac{18\eta L/t}{(G_s - 1)\rho_wg}}, \quad P = \frac{G_s}{G_s - 1}\frac{R_c}{W_s}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(L\) | Effective depth | m |
| \(t\) | Time since start | s |
| \(\eta\) | Water viscosity at test temperature | Pa·s |
| \(G_s\) | Specific gravity of solids | - |
| \(R_c\) | Corrected hydrometer reading (g/L) | - |
| \(W_s\) | Dry soil mass in 1 L suspension (g) | - |
| \(v\) | Settling velocity | m/s |
| \(D\) | Equivalent particle diameter | m |
| \(P\) | Percent finer than D | - |
Method and standards
Hydrometer.
Where it is used
- Fine soil grading for classification.
- Clay content estimates.
Common mistakes
- Using total suspension height instead of effective depth.
- Skipping the dispersant and meniscus corrections.
Assumptions and limits
- Spherical particles; laminar settling; dilute suspension.
References
- Stokes' law sedimentation analysis
Questions and answers
Why does the depth change with time?
As the hydrometer sinks less in a thinner suspension, the depth to its centre of buoyancy changes; calibration gives L for each reading.
Why only below 75 µm?
Coarser particles settle too fast and turbulently for Stokes' law; they are measured by sieving.
What do the defaults represent?
An illustrative reading after 30 minutes at 140 mm effective depth, water at about 20 °C, G_s 2.70, corrected reading 18 g/L with 50 g of soil.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Das and Sobhan, Principles of Geotechnical Engineering, 8th ed. (Cengage, 2014), Holtz, Kovacs and Sheahan, An Introduction to Geotechnical Engineering, 2nd ed. (Pearson, 2011)